Safety and Installation Instruction
Fusing Consideration
Caution: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of sophisticated power architecture. To maximum exibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a normal-blow fuse in 5Vin with maximum rating of 500mA and in 12Vin with maximum rating of
200mA. Based on the information provided in this data sheet on Inrush energy and maximum dc input current; the
same type of fuse with lower rating can be used. Refer to the fuse manufacturer’s data for further information.
MTBF and Reliability
The MTBF of TMV-EN series of DC/DC converters has been calculated using
MIL-HDBK 217F NOTICE2, Operating Temperature 25℃, Ground Benign.
Model MTBF Unit
TMV 0505EN
2,900,953
Hours
TMV 0512EN
2,926,421
TMV 0515EN
2,875,924
TMV 0505DEN
2,188,868
TMV 0512DEN
2,398,082
TMV 0515DEN
2,364,865
TMV 1205EN
2,911,814
TMV 1212EN
2,937,474
TMV 1215EN
2,886,598
TMV 1205DEN
2,138,058
TMV 1212DEN
2,364,865
TMV 1215DEN
2,364,865