Datasheet
Input Current
- at no load
24 Vin models:
6 mA typ.
48 Vin models:
6 mA typ.
110 Vin models:
2 mA typ.
Surge Voltage
24 Vin models:
50 VDC max. (1 s max.)
48 Vin models:
100 VDC max. (1 s max.)
110 Vin models:
185 VDC max. (1 s max.)
Recommended Input Fuse
24 Vin models:
1250 mA (slow blow)
48 Vin models:
630 mA (slow blow)
110 Vin models:
315 mA (slow blow)
Input Filter
Internal Capacitor
Input Specifications
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.2% max.
dual output models:
0.2% max.
- Load Variation (0 - 100%)
single output models:
0.5% max.
dual output models:
1% max. (Output 1)
1% max. (Output 2)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
- 20 MHz Bandwidth
75 mVp-p max.
50 mVp-p typ.
Capacitive Load
- single output
3.3 Vout models:
2'200 µF max.
5 Vout models:
1'100 µF max.
9 Vout models:
680 µF max.
12 Vout models:
470 µF max.
15 Vout models:
470 µF max.
24 Vout models:
180 µF max.
- dual output
5 / -5 Vout models:
680 / 680 µF max.
12 / -12 Vout models:
330 / 330 µF max.
15 / -15 Vout models:
180 / 180 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
50 ms typ. / 75 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
180% typ. of Iout max.
Transient Response
- Response Time
250 µs typ. (25% Load Step)
Output Specifications
Safety Standards
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Railway Applications
EN 50155
- Certification Documents
www.tracopower.com/overview/tmr6wir
Pollution Degree
PD 2
Safety Specifications
TMR 6WIR Series, 6 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
June 17, 2019
Page 2 / 4