Datasheet

Application Note
Created by Traco Electronic AG Arp.
www.tracopower.com
Date: September 24
th
, 2018 / Rev.: 1.5 /
Page 22 / 23
2W, Single and Dual Output
EMC Specifications (continue)
EN61000-4-4
EFT
(performance criteria B)
open circuit output test voltage ±10%
level
power line
1
±0.5KV
2
±1.0KV
3
±2.0KV
4
±4.0KV
EN61000-4-5
Surge
(performance criteria B)
level
open circuit output test voltage ±10%
1
±0.5KV
2
±1.0KV
3
±2.0KV
4
±4.0KV
EN61000-4-6
CS
(performance criteria B)
level
voltage level(EMF)
1
1V/rms
2
3V/rms
3
10V/rms
Mechanical Data
.0.01
(0.32)
Rectangular pin
0.08
(2.01)±0.5
0.36
(9.2
0)
0.13
(3.20)
BOTTOM VIEW
All Dimensions in Inches (mm)
Tolerance: X.XX ±0.02 (X.X ±0.5)
X.XXX ±0.01(X.XX ±0.25)
Pin Pitch Tolerance ±0.02(0.5)
0.16
(4.10)±0.5
0.02
(0.50)±0.05
0.44
(11.1
0)
1
2
3
5
6
7
8
0.10(2.54)
0.86(21.80)
FRONT VIEW
0.02
(0.50)
0.70(17.78)
PIN CONNECTION
PIN
SINGLE
1
- INPUT
2
+ INPUT
3
CTRL
5
NC
6
+ OUTPUT
7
- OUTPUT
8
NC
DUAL OUTPUT
- INPUT
+ INPUT
CTRL
NC
+ OUTPUT
COM
- OUTPUT