2W, Single and Dual Output
Thermal Consideration
The power module operates in a variety of thermal environments. However, sufficient cooling should be provided to help ensure reliable operation
of the unit. Heat is removed by conduction, convection, and radiation to the surrounding Environment. Proper cooling can be verified by
measuring the point as shown in the figure below. The temperature at this location should not exceed 100°C. During performance, adequate
cooling must be provided to maintain the test point temperature at or below 100°C. Although the maximum point Temperature of the power
modules is 100°C, you can limit the case temperature to a lower value for high reliability.
TOP VIEW
Part Number Structure
TMR 4812
EMC Specifications
EN61000-4-2
ESD
(performance criteria B)
Contact discharge
Air discharge
level
test voltage (KV)
level
test voltage (KV)
1
±2
1
±2
2
±4
2
±4
3
±6
3
±8
4
±8
4
±15
EN61000-4-3
RS
(performance criteria B)
level
test field strength (V/m)
1
1
2
3
3
10
Input Voltage
Range:
05xx : 4.5~9V
12xx : 9~18V
24xx : 18~36V
48xx : 36~75V
Output Voltage
10 : 3.3V
11 : 5V
09 : 9V
12 : 12V
13 : 15V
21 : ±5V
22 : ±12V
23 : ±15V