Datasheet

Application Note
Created by Traco Electronic AG Arp.
www.tracopower.com
Date: September 24
th
, 2018 / Rev.: 1.5 /
Page 16 / 23
2W, Single and Dual Output
TMR 1221
V
in min
, Full Load V
in nom
, Full Load V
in max
, Full Load
+V
out
= 18.8mV / V
out
= 14.4mV + V
out
= 17.6mV / V
out
= 14.0mV + V
out
= 17.6mV / V
out
= 15.2mV
TMR 2422
V
in min
, Full Load V
in nom
, Full Load V
in max
, Full Load
+ V
out
= 30.8mV / V
out
= 19.2mV + V
out
= 25.6mV / V
out
= 18.0mV + V
out
= 18.4mV / V
out
= 12.8mV
TMR 4823
V
in min
, Full Load V
in nom
, Full Load V
in max
, Full Load
+ V
out
= 26.8mV / V
out
= 24.4mV + V
out
= 14.8mV / V
out
= 14.0mV + V
out
= 12.8mV / V
out
= 10.4mV