Datasheet

EMC Immunity
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria A
- Surge
EN 61000-4-5, ±1 kV, perf. criteria A
Ext. Input Component:
Nippon KY 220 µF, 48 mOhm
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
EN 61000-4-8, 100 A/m, perf. criteria A
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +92°C
- Case Temperature
+100°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
6.67 %/K above 85°C
Cooling System
Natural convection (20 LFM)
Altitude During Operation
12'000 m max.
Switching Frequency
100 - 650 kHz (RCC)
Insulation System
Functional Insulation
Isolation Test Voltage
- Input to Output, 60 s
1'600 VDC
Isolation Resistance
- Input to Output, 500 VDC
1'000 MOhm min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
200 pF max.
Reliability
- Calculated MTBF
4'900'000 h (MIL-HDBK-217F, ground benign)
Environment
- Vibration
MIL-STD-810F
- Mechanical Shock
MIL-STD-810F
- Thermal Shock
MIL-STD-810F
Housing Material
Non-conductive Plastic (UL94 V-0 rated)
Potting Material
Silicone (UL94 V-0 rated)
Connection Type
THD (Through-Hole Device)
Weight
4.8 g
Remote Control
- Current Controlled Remote
On: open circuit
Off: 2 to 4 mA current (internal 1 kOhm resistor)
- External Circuit Proposal
www.tracopower.com/info/current-remote.pdf
- Off Idle Input Current
2.5 mA max.
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
General Specifications
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tmr2
TMR 2 Series, 2 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
June 3, 2019
Page 3 / 4