Datasheet

EMC Emissions
EN 61204-3 (Low Voltage Power Supplies)
- Conducted Emissions
EN 55014-1
EN 55032 class B (internal filter)
FCC Part 15, class B
- Radiated Emissions
EN 55014-1
EN 55032 class B (internal filter)
FCC Part 15, class B
- Harmonic Current Emissions
EN 61000-3-2
- Voltage Fluctuations & Flicker
EN 61000-3-3
EMC Immunity
EN 55024 (IT Equipment)
EN 55014-2 (Household Appliances Tools)
EN 61204-3 (Low Voltage Power Supplies)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±4 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria A
- Surge
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
EN 61000-4-8, 30 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria A
>95%, 0.5 periods, perf. criteria A
>95%, 250 periods, perf. criteria B
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–25°C to +70°C
- Approved Ambient Temp.
+60°C max.
- Storage Temperature
–40°C to +85°C
Power Derating
- High Temperature
5 %/K above 60°C
Cooling System
Natural convection (20 LFM)
Altitude During Operation
2'000 m max.
Switching Frequency
49 - 81 kHz (PWM)
65 kHz typ. (PWM)
Insulation System
Reinforced Insulation
Working Voltage (rated)
245 VAC
Isolation Test Voltage
- Input to Output, 60 s
3'000 VAC
Isolation Resistance
- Input to Output, 500 VDC
100 MOhm min.
Reliability
- Calculated MTBF
1'200'000 h (MIL-HDBK-217F, ground benign)
Housing Material
Plastic resin (UL 94V-0 rated)
Pin Material
Copper alloy w. gold plate over nickel subplate
Connection Type
THD (Through-Hole Device)
Weight
17.4 g
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
General Specifications
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tmps03
TMPS 03 Series, 3 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
July 3, 2019