Datasheet

EMC Immunity
EN 55024 (IT Equipment)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±4 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria A
- Surge
EN 61000-4-5, ±2 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
EN 61000-4-8, 30 A/m, perf. criteria A
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +90°C
- Case Temperature
+95°C max.
- Storage Temperature
–50°C to +125°C
Power Derating
- High Temperature
10 %/K above 85°C
Cooling System
Natural convection (20 LFM)
Remote Control
- Voltage Controlled Remote
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
- Off Idle Input Current
3 mA typ.
- Remote Pin Input Current
-0.5 to 0.5 mA
Altitude During Operation
2'000 m max.
Switching Frequency
285 kHz typ. (PWM)
Insulation System
Functional Insulation
Isolation Test Voltage
- Input to Output, 60 s
2'500 VDC
Isolation Resistance
- Input to Output, 500 VDC
1'000 MOhm min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
2'200 pF max.
Reliability
- Calculated MTBF
775'200 h (MIL-HDBK-217F, ground benign)
Housing Material
Plastic resin (UL 94V-0 rated)
Connection Type
Screw Terminal
Weight
107 g
Thermal Impedance
3.9 K/W (at 20 LFM and 70°C)
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
General Specifications
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tmdc20
TMDC 20 Series, 20 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
July 15, 2019
Page 3 / 4