Datasheet

http://www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THN 30 Series 30 Watt
Output Specifications
Max. capacitive load 3.3 VDC models: 10’000 µF
5 VDC models: 7’200 µF
12 VDC models: 1’200 µF
15 VDC models: 1’000 µF
24 VDC models: 375 µF
±12 VDC models: 750 µF (each output)
±15 VDC models: 500 µF (each output)
General Specifications
Temperature ranges – Operating without heat sink –40°C to +80°C (with derating)
– Operating with heat sink –40°C to +85°C (with derating)
– Case temperature +105°C max.
– Storage –55°C to +125°C
Power derating – Operating without heat sink 2.2 %/K above +55°C
– Operating with heat sink 2.5 %/K above +60°C
Thermal impedance – Natural convection 15.0°C/W
– Natural convection with heat sink 13.8°C/W
Thermal protection shutdown at 115°C
Humidity (non condensing) 5 % to 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +70°C, ground benign) 1.3 Mio. h
Isolation voltage (60sec.) – Input/Output 1500 VDC
– Input, Output/Case 1000 VDC
Isolation capacitance – Input/Output 1500 pF max.
Isolation resistance – Input/Output (500 VDC) >1 GOhm
Remote On/Off – On: 3.0 to 15 VDC or open circuit
– Off: 0 to 1.2 VDC or short circuit pin 6 and pin 2
– Off idle current: 2.0 mA
Switching frequency (fixed, pulse width modulation) 3.3 & 5.0 Vout models: 275 kHz ±10%
other models: 330 kHz ±10%
Vibration and thermal shock MIL-STD-810F
Safety approvals UL/cUL 60950-1 2nd +Am1, IEC/EN 60950-1
– Certification documents www.tracopower.com/overview/thn30
Physical Specifications
Casing material copper
Baseplate non conductive FR4
Potting material silicone (UL 94V-0 rated)
Weight 16.5 g (0.58oz)
Soldering temperature max. 26C / 10sec.
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Supporting documents: www.tracopower.com/overview/thn30