Datasheet
Capacitive Load
- single output
3.3 Vout models:
3'000 µF max.
5 Vout models:
2'500 µF max.
12 Vout models:
430 µF max.
15 Vout models:
350 µF max.
24 Vout models:
125 µF max.
- dual output
5 / -5 Vout models:
1'440 / 1'440 µF max.
12 / -12 Vout models:
250 / 250 µF max.
15 / -15 Vout models:
180 / 180 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
30 ms typ.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
150% typ. of Iout max.
Overvoltage Protection
112 - 151% of Vout nom.
(depending on model)
3.7 - 5 VDC (3.3 VDC model)
5.6 - 7 VDC (5 VDC model)
13.5 - 16 VDC (12 VDC model)
18.3 - 22 VDC (15 VDC model)
29.1 - 34.5 VDC (24 VDC model)
5.6 - 7 VDC (±5 VDC model)
13.5 - 18.2 VDC (±12 VDC model)
17 - 22 VDC (±15 VDC model)
Transient Response
- Response Time
250 µs typ. (25% Load Step)
Safety Standards
- Medical Equipment
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
2 x MOPP (Means Of Patient Protection)
- Certification Documents
www.tracopower.com/overview/thm10
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
EN 60601-1-2 edition 4 (Medical Devices)
- Conducted Emissions
EN 55011 class A (internal filter)
EN 55011 class B (with external filter)
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
FCC Part 18, class A
FCC Part 18, class B
- Radiated Emissions
EN 55011 class A (internal filter)
EN 55011 class B (with external filter)
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
FCC Part 18, class A
FCC Part 18, class B
External filter proposal:
www.tracopower.com/overview/thm10
EMC Specifications
THM 10 Series, 10 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
September 16, 2019
Page 3 / 5