Datasheet

Cooling System
Natural convection (20 LFM)
Remote Control
- Voltage Controlled Remote
On: 0 to 1.2 VDC or open circuit
Off: 2.2 to 12 VDC
Refers to 'Remote' and '-Vin' Pin
- Off Idle Input Current
2.5 mA typ.
- Remote Pin Input Current
-0.5 to 1.0 mA
(Only for optional models with remote-control)
Altitude During Operation
5'000 m max.
Switching Frequency
270 - 330 kHz (PWM)
300 kHz typ. (PWM)
Insulation System
Reinforced Insulation
Isolation Test Voltage
- Input to Output, 60 s
5'000 VAC
Creepage
- Input to Output
8 mm min.
Clearance
- Input to Output
8 mm min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
12 pF typ.
17 pF max.
Leakage Current
- Touch Current
2 µA max. (240 VAC, 60 Hz)
Reliability
- Calculated MTBF
3'850'000 h (MIL-HDBK-217F, ground benign)
Environment
- Vibration
MIL-STD-810F
- Thermal Shock
MIL-STD-810F
Housing Material
Non-conductive Plastic (UL94 V-0 rated)
Base Material
Non-conductive Plastic (UL 94 V-0 rated)
Potting Material
Silicone (UL 94 V-0 rated)
Soldering Profile
265°C / 10 s max.
Connection Type
THD (Through-Hole Device)
Weight
14 g
Thermal Impedance
18 K/W
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thm10wi
THM 10WI Series, 10 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
September 16, 2019
Page 4 / 5