Datasheet
Application Note
Created by Traco Electronic AG Arp. www.tracopower.com Date: July 5
th
, 2012 / Rev.: 2.0 / Page 3 / 44
3W SINGLE & DUAL
OutputSpecification(Continued)
Parameter Model Min Nominal Max Unit
THL 3-xx10WI 90 600
THL 3-xx11WI 90 600
THL 3-xx12WI 38 250
THL 3-xx13WI 30 200
THL 3-xx15WI 19 125
THL 3-xx21WI ±45 ±300
THL 3-xx22WI ±19 ±125
Output Current
THL 3-xx23WI ±15
±100
mA
Output Over Current Protection All 110 %FL
Output Short Circuit Protection All Continuous
InputSpecification
Parameter Model Min Nominal Max Unit
Operating Input Voltage THL 3-24xxWI 9 24 36
THL 3-48xxWI 18 48 75
Vdc
Under Voltage Lockout Turn-on Threshold THL 3-24xxWI 4.5 6 8.5
THL 3-48xxWI 8.5 12 17
Vdc
Under Voltage Lockout Turn-off Threshold THL 3-24xxWI 8
THL 3-48xxWI 16
Vdc
Input reflected ripple current
(5 to 20MHz, 12μH source impedance)
All 5 mA pk-pk
THL 3-2410WI 110
THL 3-2411WI 160
THL 3-2412WI 156
THL 3-2413WI 156
THL 3-2415WI 156
THL 3-2421WI 162
THL 3-2422WI 156
THL 3-2423WI 156
THL 3-4810WI 55
THL 3-4811WI 80
THL 3-4812WI 78
THL 3-4813WI 78
THL 3-4815WI 78
THL 3-4821WI 81
THL 3-4822WI 78
Input Current
(Maximum value at V
in
= V
in nom
; Full Load)
THL 3-4823WI 78
mA