Datasheet
THI 2M Series
Application Note
http://www.tracopower.com Page 24 of 25
Part Number Structure
Model
Number
Input
Range
(VDC)
Output
Voltage
(VDC)
Max. Output
Current
(mA)
Input Current
at Full Load
(1)
(mA)
Efciency
(2)
(%)
THI 2-0511M 4.5-5.5 5 400 606 66
THI 2-0512M 4.5-5.5 12 165 600 66
THI 2-0513M 4.5-5.5 15 133 605 66
THI 2-0522M 4.5-5.5 ±12 ±83 553 72
THI 2-0523M 4.5-5.5 ±15 ±66 542 73
THI 2-1211M 10.8-13.2 5 400 253 66
THI 2-1212M 10.8-13.2 12 165 250 66
THI 2-1213M 10.8-13.2 15 133 252 66
THI 2-1222M 10.8-13.2 ±12 ±83 224 74
THI 2-1223M 10.8-13.2 ±15 ±66 220 75
THI 2-2411M 21.6-26.4 5 400 126 66
THI 2-2412M 21.6-26.4 12 165 125 66
THI 2-2413M 21.6-26.4 15 133 126 66
THI 2-2422M 21.6-26.4 ±12 ±83 112 74
THI 2-2423M 21.6-26.4 ±15 ±66 110 75
Note 1. Maximum value at nominal input voltage and full load of standard type.
Note 2. Typical value at nominal input voltage and full load.
THI 2-2413M
Input Voltage
05: 5V
12: 12V
24: 24V
Output Mode
1: Single
2: Dual (±)
Output Voltage
1: 5V
2: 12V
3: 15V
Max. Output Power
2W
Feature
M: Medical