Application Note
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Rev. April 13. 2015
Safety and Installation Instruction
Fusing Consideration
Caution: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of sophisticated power architecture. To maximum exibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a normal-blow fuse in 5Vin with maximum rating of 1A, in 12Vin with maximum rating of 500mA,
in 24Vin with maximum rating of 250mA and in 48Vin with maximum rating of 120mA. Based on the information
provided in this data sheet on Inrush energy and maximum dc input current; the same type of fuse with lower rating
can be used. Refer to the fuse manufacturer’s data for further information.
MTBF and Reliability
The MTBF of TES 2N series of DC/DC converters has been calculated using
MIL-HDBK 217F NOTICE2, Operating Temperature 25℃, Ground Benign.
Model MTBF Unit
TES 2N-0510
1,360,729
Hours
TES 2N-0511 1,699,813
TES 2N-0512 1,389,082
TES 2N-0513 1,389,082
TES 2N-0521 1,340,123
TES 2N-0522 1,366,867
TES 2N-0523 1,366,867
TES 2N-1210 1,370,238
TES 2N-1211 1,370,238
TES 2N-1212 1,403,115
TES 2N-1213 1,403,115
TES 2N-1221 1,353,363
TES 2N-1222 1,380,643
TES 2N-1223 1,380,643
TES 2N-2410 1,365,934
TES 2N-2411 1,365,934
TES 2N-2412 1,407,856
TES 2N-2413 1,407,856
TES 2N-2421 1,347,709
TES 2N-2422 1,374,759
TES 2N-2423 1,374,759
TES 2N-4810 1,367,428
TES 2N-4811 1,367,428
TES 2N-4812 1,394,895
TES 2N-4813 1,394,895
TES 2N-4821 1,331,381
TES 2N-4822 1,357,773
TES 2N-4823
1,357,773