Datasheet
TES 2M Series
Application Note
http://www.tracopower.com Page 20 of 26
Testing Congurations
Peak-to-peak output ripple & noise measurement test up
+Out
-Out
+Vin
-Vin
Single Output
DC / DC
Converter
Resistive
Load
Scope
Copper Strip
Cout
Copper Strip
+Out
-Out
+Vin
-Vin
Dual Output
DC / DC
Converter
Resistive
Load
Scope
Copper Strip
Cout
Com.
Scope
Cout
Copper Strip
Copper Strip
Output voltage and efciency measurement test up
üüü
V
+Vin
-Vin
V
-Vo
+Vo
Load
CONTACT AND DISTRIBUTION LOSSES
CONTACT AND DISTRIBUTION LOSSES