Datasheet

Characteristic Curves
TES 1 Series
Specifications can be changed without notice!
Make sure you are using the latest documentation, downloadable at www.tracopower.com
Application note: TES1-characteristic-curves,
page 4 of 24, rev.: 22. April 2016
All test conditions are at 25°C. The figures are identical for all TES 1-0512 models.
30
40
50
60
70
80
90
20
40
60
80
100
% of Full Load
Efficiency(%)
4.5V
5V
5.5V
Input Voltage(V)
Efficiency(%)
Efficiency vs. Output Current Efficiency vs. Input Voltage at full load
Typical Output Ripple and Noise.
Vin =Vin nom; Full Load; TA
Typical Input Start-Up and Output Rise Characteristic
Vin = Vin nom ; Full Load
~
]
Ambient Temperature
Output Power (%)
0
20
40
60
80
100
-40 0 20 60 100
110
8040
400LFM
200LFM
100LFM
Natural
convection
Derating Output Current Versus Ambient Temperature and
Airflow
Vin = Vin nom
Conduction Emission of EN55022 Class A
Vin = Vin nom ; Full Load