Datasheet
EMS Immunity
EN 50155 (Railway Applications)
EN 50121-3-2 (EMC for Rolling Stock)
EN 55024 (IT Equipment)
EN 61204-3 (Low Voltage Power Supplies)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 20 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria A
- Surge
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +95°C
- Storage Temperature
–40°C to +105°C
Power Derating
- High Temperature
See application note:
www.tracopower.com/overview/teq100wir
Over Temperature
Protection Switch Off
105°C min. / 110°C typ. / 120°C max. (Auto-
matic recovery)
Cooling System
Natural convection (20 LFM)
Sense Function
10% max. of Vout nom.
Remote Control
- Voltage Controlled Remote
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
- Off Idle Input Current
7 mA max.
- Remote Pin Input Current
-0.5 to 1.0 mA
Altitude During Operation
2'000 m max.
Switching Frequency
300 kHz typ. (PWM) (±10%, 110 VDC models)
250 kHz typ. (PWM) (±10%, other outp. models)
Insulation System
Reinforced Insulation
Isolation Test Voltage
- Input to Output, 60 s
1'591 VAC
- Input to Case, 60 s
1'131 VAC
- Output to Case, 60 s
1'131 VAC
Isolation Resistance
- Input to Output, 500 VDC
1'000 MOhm min.
Reliability
- Calculated MTBF
711'000 h (MIL-HDBK-217F at 55°C, ground
benign)
Environment
- Vibration
MIL-STD-810F
EN 61373
- Mechanical Shock
MIL-STD-810F
EN 61373
- Thermal Shock
MIL-STD-810F
Housing Material
Aluminium
Potting Material
Silicone (UL 94 V-0 rated)
Connection Type
Clip
Weight
800 g
Thermal Impedance
1.45 K/W
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
- Flammability (EN 45545-2)
www.tracopower.com/info/en45545-declaration.pdf
General Specifications
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/teq100wir
TEQ 100WIR Series, 100 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
August 5, 2019
Page 3 / 4