Datasheet
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +75°C
- Case Temperature
+105°C max.
- Storage Temperature
–55°C to +125°C
Power Derating
- High Temperature
See application note:
www.tracopower.com/overview/tep200wir
Over Temperature
Protection Switch Off
- Protection Mode
115°C typ. (Automatic recovery at 105 °C)
- Measurement Point
Base-Plate
Cooling System
Natural convection (20 LFM)
Sense Function
10% max. of Vout nom.
(Sense line to be connected to the output either
at the module or at the load under regard of po-
larity.)
Remote Control
- Voltage Controlled Remote
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
- Off Idle Input Current
3 mA typ.
- Remote Pin Input Current
-0.5 to 1.0 mA
Altitude During Operation
2'000 m max.
Switching Frequency
225 - 275 kHz (PWM)
250 kHz typ. (PWM)
Insulation System
Reinforced Insulation
Isolation Test Voltage
- Input to Output, 60 s
3'000 VAC (110 Vin models)
2'121 VAC (other models)
- Input to Case, 60 s
1'500 VAC (110 Vin models)
1'121 VAC (other models)
- Output to Case, 60 s
1'500 VAC (110 Vin models)
1'121 VAC (other models)
Isolation Resistance
- Input to Output, 500 VDC
1'000 MOhm min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
2'500 pF max.
Reliability
- Calculated MTBF
300'000 h (MIL-HDBK-217F, ground benign)
Environment
- Vibration
MIL-STD-810F
EN 61373
- Mechanical Shock
MIL-STD-810F
EN 61373
- Thermal Shock
MIL-STD-810F
Housing Material
Alu base-plate w. plastic case (110 Vin models)
Alu base-plate w. metal case (other models)
Base Material
Non-conductive FR4 (UL94 V-0 rated) (24 Vin &
48 Vin models only)
Potting Material
Silicone (UL 94 V-0 rated)
Connection Type
THD (Through-Hole Device)
Weight
105 g
Thermal Impedance
6.1 K/W
- with Heat Sink
4.6 K/W
Environmental Compliance
- Reach
www.tracopower.com/info/reach-declaration.pdf
- RoHS
www.tracopower.com/info/rohs-declaration.pdf
- Flammability (EN 45545-2)
www.tracopower.com/info/en45545-declaration.pdf
General Specifications
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tep200wir
TEP 200WIR Series, 200 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
September 17, 2019
Page 4 / 5