Datasheet
Capacitive Load
- 24 Vin input
3.3 Vout models:
151'000 µF max.
5 Vout models:
72'000 µF max.
12 Vout models:
12'500 µF max.
15 Vout models:
8'000 µF max.
24 Vout models:
3'100 µF max.
28 Vout models:
2'300 µF max.
48 Vout models:
770 µF max.
- 48 Vin input
3.3 Vout models:
151'000 µF max.
5 Vout models:
80'000 µF max.
12 Vout models:
15'000 µF max.
15 Vout models:
9'300 µF max.
24 Vout models:
3'700 µF max.
28 Vout models:
2'600 µF max.
48 Vout models:
930 µF max.
- 110 Vin input
3.3 Vout models:
172'000 µF max.
5 Vout models:
88'000 µF max.
12 Vout models:
16'600 µF max.
15 Vout models:
10'600 µF max.
24 Vout models:
4'100 µF max.
28 Vout models:
3'000 µF max.
48 Vout models:
1'000 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
75 ms typ.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
120 - 150% of Iout max.
Overvoltage Protection
115 - 130% of Vout nom.
Transient Response
- Response Time
200 µs typ. / 250 µs max. (25% Load Step)
Safety Standards
- IT / Multimedia Equipment
IEC 60950-1
EN 60950-1
UL 60950-1
- Railway Applications
EN 50155
- Certification Documents
www.tracopower.com/overview/tep200wir
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
- Conducted Emissions
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
- Radiated Emissions
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
External filter proposal:
www.tracopower.com/overview/tep200wir
EMS Immunity
EN 50155 (Railway Applications)
EN 50121-3-2 (EMC for Rolling Stock)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 20 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
Ext. input component:
24 & 48 Vin models: 2 x KY 20 µF
110 Vin models: 2 x KXJ 150 µF
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
EMC Specifications
TEP 200WIR Series, 200 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
September 17, 2019