Datasheet

Options
TEN-HS1
- Heat-sink with clamps
on demand
(backorder with MOQ
non stocking item)
- Models with factory assembled heat-sink
- Models with inverse remote control
Input Current
- At no load
12 Vin models:
20 mA typ.
24 Vin models:
15 mA typ.
48 Vin models:
10 mA typ.
Surge Voltage
12 Vin models:
25 VDC max. (1 s max.)
24 Vin models:
50 VDC max. (1 s max.)
48 Vin models:
100 VDC max. (1 s max.)
Under Voltage Lockout
12 Vin models:
7 VDC min. / 8 VDC typ. / 8.8 VDC max.
24 Vin models:
15 VDC min. / 16 VDC typ. / 17.5 VDC max.
48 Vin models:
32 VDC min. / 33 VDC typ. / 35 VDC max.
Recommended Input Fuse
12 Vin models:
8'000 mA (fast acting)
24 Vin models:
4'000 mA (slow blow)
48 Vin models:
2'000 mA (slow blow)
Input Filter
Internal Pi-Type
Input Specifications
Output Voltage Adjustment
–10% to +20% (By external trim resistor) (15 &
24 Vout models)
±10% (By external trim resistor) (other models)
(Single models only)
See application note:
www.tracopower.com/overview/ten40e
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.2% max.
- Load Variation (0 - 100%)
single output models:
0.3% max.
dual output models:
0.5% max. (Output 1)
0.5% max. (Output 2)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
(20 MHz Bandwidth)
- single output
3.3 Vout models:
75 mVp-p typ.
5 Vout models:
75 mVp-p typ.
12 Vout models:
100 mVp-p typ.
15 Vout models:
100 mVp-p typ.
24 Vout models:
150 mVp-p typ.
- dual output
12 / -12 Vout models:
100 / 100 mVp-p typ.
15 / -15 Vout models:
100 / 100 mVp-p typ.
24 / -24 Vout models:
150 / 150 mVp-p typ.
Capacitive Load
- single output
3.3 Vout models:
22'000 µF max.
5 Vout models:
12'000 µF max.
12 Vout models:
2'000 µF max.
15 Vout models:
1'300 µF max.
24 Vout models:
490 µF max.
- dual output
12 / -12 Vout models:
980 / 980 µF max.
15 / -15 Vout models:
630 / 630 µF max.
24 / -24 Vout models:
250 / 250 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
30 ms typ. / 60 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
150% typ. of Iout max.
Output Specifications
TEN 40E Series, 40 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
September 27, 2019
Page 2 / 4