User Manual

7
Drag Brake
Brake Strength
Initial Brake
Brake Rate Switch Point
1st Stage Brake Rate
2nd Stage Brake Rate
Brake Input Curve
Brake
Control
0-100%(in 1% increment)
0-100%
=Drag Brake
1-99%(in 1% increment)
1-20
1-20
Line
0-50%
Custom
If you set the cut-off voltage manually, please note the adjustable voltage is TOTAL cut-off
voltage of the battery pack.
Data
Storage
Mode
Start and Stop Control
Choose data types to save
Data Saving Time increment
Single
Start storage once entering
in main program
Cycle
Press control storage
entering in main program
0.1S-10S
Voltage
Current
Throttle
Current
RPM
ESC
Temperature
Profiles Preset
Profile One Setting Value (Default Value)
Running Mode
Motor Direction
Reverse Speed
Voltage Cutoff
ESC Overheat Protection
Program Item
Section
General
Setting
Description
Forward/Brake
Normal
25%
22.6V
105/221
BEC Voltage
6V
You can present and store 10 sets of profiles in the ESC. These data could be deployed at any
time. You can also reset the profile according to your request.