User's Guide
Using the Alerta System
The system is designed to connuously monitor
a person wearing a Patch. The monitoring is
done by a hand held device called the Wedge. This is a
one on one relaonship between the Patch and the
Wedge over a fixed distance. The distance of the Safe
Zone is 75 to 90 feet, depending on the structure and
environment where it is used. As such, it will give the
person maximum flexibility while keeping them in line of
sight. The proximity can be modified by the caregiver by
Track Patch I corporaon uses recycled components
and assemblies in the manufacturing of the Alerta Patch
and Wedge. The company also will also dispose of all
baeries returned in accordance with applicable laws
and regulaons.
Addional Product Informaon
placing the Wedge in a closer or further proximity to
the Patch. This is facilitated by the Signal Strength
indicator. The more signal, the closer the person is and
the caregiver can get ample warning before an alarm.
Since the system works well when the person is sing
or lying down, they can be monitored easily in normal
living.
Safety
Recycling
Legal Info
some users. Be sure the patch placement area is free of
hair and clean.
The Patch baery cannot be replaced by the user. The
Patch must be returned to Track Patch for Recycle and
Baery replacement. If the Patch is not returned, it
must be disposed of in compliance with applicable laws
and regulaons.
Model Number: TPGSK001.
Electrical Rang: 3.0 V Baery Powered
Wedge: two Special AA Lithium Baeries
Patch: 1 long life Lithium coin cell
The designated operang temperature of the system is 0-35º C.
Regulatory Informaon
This device (FCC ID 2AUWF-TPPW0001) complies with part 15 of the
FCC Rules. Operaon is subject to the following two condions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operaon.
Changes or modificaons not expressly approved by the party
responsible for compliance could void the user's authority to operate
the equipment.
Frequency band 915 MHz Max RF
Alerta uses 3M medical grade foam tape and
adhesives tested for long term use. However, the
patch may contribute to skin irritaon or allergies in
Out of Range
An alarm will sound and the Out of Range light will flash
when the Wedge has lost contact with the Patch. This is
the indicaon that will most oen mean the person
wearing the Patch has wandered more than 75FT from
the caregiver. This is a Hard Alarm (HA). When triggered,
the alarm will sound unl the reset buon is pushed, or
it unl it mes out aer 2.5 minutes. If the individual
wearing the Patch returns to the Safety Zone, the alarm
will stop and monitoring will resume. On occasion the
Wedge will alarm because of some transient interrup-
on. This is a False Posive Alarm (FPA). This alarm will
reset automacally.
Reset
The reset buon turns the Wedge on for pairing with
the Patch and resets an alarm when one occurs
Baery Level
The Baery Level indicator will light up when the baery
in the Wedge must be changed immediately.
See www.trackpatch.com for baery change instruc-
ons, using the spare baery shipped in the tray.