User Manual
MN March22 www.tqbbrands.com.au Page 2 of 3
5. Remove the 6 Control panel screws and reveal and unplug the Pump Cable from the rear of
the circuit board.
Note: the circuit board plug sockets are marked with the plug descriptions.
6. Cut the Pump Cable, cable ties, and wind the insulation off the lower
loom bulkhead fitting. Loosen the lower bulkhead fitting nut and pull
the old cable through the lower bulkhead fitting from the control
panel side.
7. Install the new pump in the reverse of removal instructions including reconnection
of the water supply hose.
8. Reattach the cable to the loom with new cable ties and rewind the insulation up to the
lower bulkhead.
9. Feed the pump cable plug through the bulkhead fitting leaving approximately
200mm of cable on the circuit board side. Ensure the thread cable and cable
braid back together.
10. Connect the pump cable plug to the control panel then loop the extra cable and cable tie
it, tucking this behind the control panel. Refit the control panel with the screws. Ensure
the thread cable and cable braid back together.