WIRING (continued)
FES-1024-1CA, FES-0924-1C
Models FES-1024-1CA and FES-0924-1C are
shipped with a cordset factory-installed. This
cordset contains a plug for use with a 50A household
range receptacle. The blade conguration on the
plug included on these heaters is represented in
g. 1 below (4-wire circuit).
The range receptacle you choose to use may
have a blade conguration compatible with the
plug shown in g. 2 (3-wire circuit). This is an
older branch circuit design that does not include
a separate equipment grounding conductor
(green wire). The conguration in g. 1 has been
implemented on newer branch circuit installations
for increased safety, and is now the required
circuit conguration by the National Electric Code.
Changing a 3-wire branch circuit and receptacle to
4-wire design may involve changes to your range
and must only be done by a licensed electrician.
240 VOLT / 2500 WATT ELEMENTS
TYP. 4
CONTACTOR
COIL
CONTACTOR
COIL
OVER-TEMP.
SWITCH
CYCLING
NON-CYCLING
FAN
MOTOR
GROUND
LUG
240 VOLT 50/60 Hz
1-PHASE 10KW
GREEN
WHITE
RED
BLACK
g. 1 g. 2
ELECTRICAL SHOCK HAZARD
RISQUE DE CHOC ÉLECTRIQUE
• Serious injury or
death may occur.
Blessures graves ou la mort peuvent
survenir.
• Plug heater into a 4-wire
receptacle rated 50A.
Chauffage Branchez un circuit à 4
ls prise nominale 50A.
• Any and all changes to branch
circuits and receptacles
MUST be done by a
licensed electrician ONLY.
Toutes les modications et tous
les circuits de dérivation et de
récipients doivent être effectués par
un électricien agréé SEULEMENT.