Cut Sheet

9
Unit with optional control section containing
disconnect, pilot light, and thermostat
(Sufx C1-TDP)
Standard Unit
FEP Series Three Phase Hazardous Location Wall Convector
Dimensions: Height 5 5/8’’, Width 6 3/8’’, Depth 4 1/2’
Finish: Silver-Gray
Type: Single or Double Pole
Remote Mounted Hazardous Location Thermostats For Single Phase Models Only
Cabinet size 18” high, 9” wide.
Bottom In - Top Out air ow.
Wall mounting bracket supplied.
Units can not be operated in room ambients exceeding 104
O
F (40
O
C).
Heavy duty 16 Gauge steel with gray epoxy textured powder coated nish.
9” minimum clearance from bottom of heater to oor required.
Stainless steel cartridge element inserted into Aluminum nned Copper sheath.
Standard unit (without EPET thermostat or control section) is NEMA 4 rated.
Motor Rating: (full load) 1 1/2 HP @ 250V
Rating: 22A @ 125-277VAC; 125VA @ 24VAC
Rated: Class I Group C & D, Class II Group E, F, G
Thermostat is not rated for use in Group B environments.
EPET Series Parameters
HLT Series
ABS (American Bureau of Shipping) type approved.
*T1 and T2 option not available on 3 phase models
Factory Installed Control Options
**Remove - RA sufx and
add new sufx (Not NEMA
washdown rated or rated for
Group B atmospheres)
Note: C1-TD and C1-TDP are only options available for 3 phase units.
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
T-2A SERIES THREE PHASE
Class 1, Group B, C, & D Divisions 1 & 2 280° C / 536° F
UPC
MODEL WATTS BTU's VOLTS AMPS
CABINET
WT.
(LBS.)
LIST
686334 LENGTH
483056 FEP-1820-3RA
1800 6143
208 5.0
34” 50
1719
483063 FEP-1824-3RA 240 4.3
486224 FEP-1848-3RA 480 2.2 1869
483070 FEP-3620-3RA
3600 12286
208 10.0
34” 54
2622
483087 FEP-3624-3RA 240 8.7
486231 FEP-3648-3RA 480 4.3 2726
483094 FEP-3820-3RA
3800 12969
208 10.5
58” 80
2784
483100 FEP-3824-3RA 240 9.1
486248 FEP3848-3RA 480 4.6 2999
483117 FEP-7620-3RA
7600 25938
208 21.1
58” 85 3223483124 FEP-7624-3RA 240 18.3
486255 FEP-7648-3RA 480 9.2
T-3A SERIES THREE PHASE
Class 1, Group B, C & D Division 1 & 2 180° C / 356° F
483131 FEP-0820-3RA
800 2730
208 2.2
34” 50
1719
483148 FEP-0824-3RA 240 1.9
486262 FEP-0848-3RA 480 0.9 1869
483155 FEP-1620-3RA
1600 5460
208 4.4
34” 54
2622
483162 FEP-1624-3RA 240 3.8
486279 FEP-1648-3RA 480 1.9 2726
483179 FEP-1720-3RA
1700 5802
208 4.7
58” 80
2784
483186 FEP-1724-3RA 240 4.1
486286 FEP-1748-3RA 480 2.0 2999
483193 FEP-3420-3RA
3400 11604
208 9.4
58” 85 3192483209 FEP-3424-3RA 240 8.2
486293 FEP-3448-3RA 480 4.1
SUFFIX** DESCRIPTION
LIST
C1-TD Control section with transformer, 24V contactor, SP thermostat (40
O
F - 90
O
F) and disconnect switch (all units) 1971
C1-TDP
Control section with transformer, 24V contactor, SP thermostat (40
O
F - 90
O
F), disconnect switch & pilot light (all units)
2047
UPC#
686334
MODEL DESCRIPTION LOAD RATINGS RANGE LIST
538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90
o
F 453
538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90
o
F 429
528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90
o
F 467
528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90
o
F 442
523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110
o
F 476
523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110
o
F 502
Master ctn: 4 pcs, 24 llbs (varies slightly by model), 16” x 14.5” x 6”
EPET Series incorporates plastic knob & Bi-Metal Sensor housing.
HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb and capillary sensor.
HLT Series