Product Manual

ISSUE DATE 10-09-03 REV. DATE 2-26-09 REV. LEVEL: 14 ECO 1-6073 OIPM P/N 8329 PG 16 OF 17
OPTIONAL WIRE GUARD INSTALLATION
CAUTION: DISCONNECT POWER BEFORE
INSTALLING OR SERVICING. IF THE POWER
DISCONNECT IS OUT OF SIGHT, LOCK IT IN TH
E
OPEN POSITION AND TAG IT TO PREVENT
UNEXPECTED APPLICATION OF POWER.
FAILURE TO DO SO COULD RESULT IN FATAL
ELECTRICAL SHOCK.
Mounting holes for attaching the lamp guard are provided in
heater housing. NOTE: Mounting holes are not
provided on
older models. Using the drill starts provided in t
he heater
housing, drill a 1/8” diameter hole at each location. (See
dimensional details.)
1.
Place mounting clips provided, on the loops of the lamp
guard (see Detail A below).
2. Attach the lamp guard to the heater using the #8 sheet
metal screws provided.
MAINTENANCE
CAUTION: Disconnect power before installing or servicing.
If the power disconnect is out of sight, lock it in the open
position and tag it to prevent unexpected application of
power. Failure to do so could result in fatal electrical shock.
To service the heater in the overhead position, it will be necessary
to remove the screws from only one side of the lamp guard. The
lamp guard will then swing clear of the heater.
Heater Series
Wire Guard
Part Number
222
CHWG-222-A
08511500
223
CHWG-223
08543600
342
CHWG-342
08511400
343
CHWG-343
08543500
462
CHWG-462
08516200
463
CHWG-463
08543400
Clip
Attachment
Detail
Detail A