Product Manual
ISSUE DATE 7/2015 REV. DATE- REV. LEVEL: - ECO 1-7092 OIPM P/N 8420 PG 10 OF 11
When power is provided to these heaters the heater
elements will take several minutes to achieve full
infrared output that can be conrmed by an orange
to dull red glow on the element face
.
The element
coil under this condition is operating between
1,500 and 1,600° F emitting medium wave
length (approx. 3 microns or millionths of a
meter) infrared energy.
T
his energy, that
can also be considered “radiation” is not
harmful, yet is very effective at heating
objects and surfaces that are within the
line-of-sight of the elements and the
heater’s reective surfaces.
When power is provided or removed from these
heaters, you may hear unfamiliar sounds that are
caused by the expansion and contraction of metal
components in the heater. This is normal.
There are no on/off switches, tip-over switches or
over-temperature safety cut out devices included
on any of these heaters.
See the Accessories
section of this manual for more details.
EXPLOSION HAZARD
FIRE HAZARD
BURN HAZARD
• Serious injury or death may
occur.
• Always operate heaters on
level surfaces.
• Allow heater to fully cool after
power is removed before
touching or working on it.
• Do not leave heaters unat-
tended while in operation.
• Maintain minimum clearances
to combustibles as shown in
table below.
OPERATION
MODEL
REQUIRED CLEARANCES
TO COMBUSTIBLES FROM
FRONT OF HEATER
FSP-1412-1C 3 FEET
FSP-31 3 FEET
FSP-43 4 FEET
FSP-95 7 FEET