Business Networking Solution Installation Guide Jetstream L2 Managed Switch TL-SG5412F/T2500G-10MPS/T2600G-28SQ T2500G-10TS (TL-SG3210)/T2500-28TC (TL-SL5428E) T2600G-18TS (TL-SG3216)/T2600G-28TS (TL-SG3424) T2600G-52TS (TL-SG3452)/T2600G-28MPS (TL-SG3424P)
About this Installation Guide This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during the installation. This Installation Guide is structured as follows: Chapter 1 Introduction This chapter describes the external components of the switch. Chapter 2 Installation This chapter illustrates how to install the switch. Chapter 3 Connection This chapter illustrates how to do the physical connection of the switch.
Contents Chapter 1 Introduction———————————— 01 1.1 1.2 Product Overview............................................................01 Appearance........................................................................01 Chapter 2 Installation———————————— 07 2.1 Package Contents...........................................................07 2.3 Installation Tools...............................................................09 2.2 2.4 Safety Precautions..................................................
JetStream L2 Managed Switch Chapter 1 Introduction 1.1 Product Overview Designed for workgroups and departments, TP-Link JetStream L2 Managed Switch provides wirespeed performance and abundant L2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. ACL, 802.
JetStream L2 Managed Switch The front panel of T2500G-10MPS is shown as the following figure. Figure 1-3 Front Panel of T2500G-10MPS LED Mode Switch Button LEDs Console Port (RJ-45/USB) 10/100/1000Mbps SFP Port RJ45 Port The front panel of T2500-28TC is shown as the following figure. Figure 1-4 Front Panel of T2500-28TC LEDs Console Port 10/100Mbps RJ45 Port 10/100/1000Mbps RJ45 Port SFP Port The front panel of T2600G-18TS is shown as the following figure.
JetStream L2 Managed Switch The front panel of The T2600G-28MPS is shown as the following figure. Figure 1-8 Front Panel of T2600G-28MPS Console Port LED Mode Switch Button (RJ45/USB) LEDs SFP Port 10/100/1000Mbps RJ45 Port The front panel of The T2600G-28SQ is shown as the following figure.
JetStream L2 Managed Switch LED 1000M 10/100/1000M Indication Green On: Running at 1000Mbps, but no activity. Green Flashing: Running at 1000Mbps and is transmitting or receiving data. Yellow On: Running at 10/100Mbps, but no activity. Yellow Flashing: Running at 10/100Mbps and is transmitting or receiving data. 10/100/1000BASE-T Off: No device is linked to the corresponding port.
JetStream L2 Managed Switch LED Indication PoE Max On: The remaining PoE power≤7W. is on) Off: The remaining PoE power >7W. (When the PoE LED Speed or PoE (When the Speed LED is on) Flashing: The remaining PoE power keeps≤7W after this LED is on for 2 minutes. Green On: Running at 1000Mbps, but no activity. Green Flashing: Running at 1000Mbps and is transmitting or receiving data. Yellow On: Running at 10/100Mbps, but no activity.
JetStream L2 Managed Switch A Combo port consists of one RJ45 port and one SFP port, and they share the same port ID. The SFP port and the associated RJ45 port cannot work simultaneously. If both of the two ports are connected, only the SFP port works. For T2500-28TC, RJ45 ports 25-28 and SFP ports 25-28 are combo ports; For T2600G-28SQ, RJ45 ports 21-24 and SFP ports 21-24 are combo ports.
JetStream L2 Managed Switch Chapter 2 Installation 2.1 Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Switch One Power Cord, One Console Cable and One USB Cable Installation Guide Business Networking Solution Installation Guide One Resouce CD Two mounting brackets and the fittings Note: The USB Cable is not provided with TL-SG5412F/T2500-28TC. 2.
JetStream L2 Managed Switch ■■ Site Requirements Temperature/Humidity 40℃ 0℃ Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table.
JetStream L2 Managed Switch Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken. ■■ ■■ ■■ ■■ Ensure the rack and device are well earthed. Make sure the power socket has a good contact with the ground.
JetStream L2 Managed Switch 2. Remove the adhesive backing papers from the rubber feet. 3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device. Figure 2-1 Desktop Installation Feet Bottom of the Device Notch ■■ Rack Installation To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Check the grounding and stability of the rack. 2.
JetStream L2 Managed Switch Caution: Please set 5 to 10cm gaps around the device for air circulation. Please avoid any heavy thing placed on the device. Please mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation.
JetStream L2 Managed Switch Chapter 3 Connection 3.1 Ethernet Port Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. Figure 3-1 Connecting the RJ45 Port RJ45 Port 3.2 RJ45 Cable SFP Port The following figure demonstrates the connection of SFP port to an SFP module. Figure 3-2 Inserting the SFP Module SFP Slot SFP Module 3.
JetStream L2 Managed Switch Figure 3-3 Connecting the Console (RJ-45) Port Console(RJ45) Connect the Console (USB) port of the device with your computer by the USB cable as the following figure shows. Figure 3-4 Connecting the Console (USB) Port Console(USB) T2600G-28T S Note: Console (RJ-45) port and Console (USB) port cannot be used cocurrently. Console (USB) port takes priority over the Console (RJ-45) port. The Console (USB) port is hot-pluggable while the Console (RJ-45) port is not.
JetStream L2 Managed Switch 3.5 Power On Plug in the negative connector of the provided power cord into the power socket of the device, and the positive connector into a power outlet as the following figure shows. Figure 3-5 Connecting to Power Supply 100-240V~5 0/60H z 0.5A Note: The figure is to illustrate the application and principle. The power plug you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above.
Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? 1. Connect the console port of the PC to the console port of the switch and open a terminal 2. Power off and restart the switch. Perform the action indicated by the terminal emulation program to reach the bootUtil menu. The action differs from product to product. Possible actions are listed below: emulation program. • 3. 4. • Press any key to stop autoboot. Press CTRL-B to reach the bootUtil menu.
Appendix B Hardware Specifications Item Standards Content IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3z, IEEE 802.3x, IEEE 802.1p, IEEE 802.1q, IEEE 802.1x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1ab IEEE 802.3af/at (For T2500G-10MPS/T2600G-28MPS) 10Base-T: UTP/STP of Cat. 3 or above 100Base-TX: UTP/STP of Cat. 5 or above Transmission Medium 100Base-FX/LX10/BX10: MMF or SMF SFP Module (For T2500G-10MPS) 1000Base-T: 4-pair UTP (≤100m) of Cat. 5e, and Cat.
FCC STATEMENT Product Name: JetStream L2 Managed Switch Model Number: TL-SG5412F/T2500G-10MPS/T2600G-28SQ/T2500G-10TS/T2500-28TC/T2600G18TS/T2600G-28TS/T2600G-52TS /T2600G-28MPS Responsible party: TP-Link USA Corporation, d/b/a TP-Link North America, Inc. Address: 145 South State College Blvd. Suite 400, Brea, CA 92821 Website: http://www.tp-link.com/us/ Tel: +1 626 333 0234 Fax: +1 909 527 6803 E-mail: sales.usa@tp-link.
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам нормативних документів та вимогам, що передбачені чинними законодавчими актами України. Safety Information • Keep the device away from water, fire, humidity or hot environments. • Do not use damaged charger or USB cable to charge the device. • Do not attempt to disassemble, repair, or modify the device. • Do not use any other chargers than those recommended.
Explanation of the symbols on the product label Symbol Explanation AC voltage Indoor use only RECYCLING This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
For technical support, User Guide and other information, please visit http://www.tp-link.com/support, or simply scan the QR code © 2018 TP-Link 7106508053 REV3.1.