Operation Manual

Table Of Contents
285
15.1.1 Global Config
On this page you can configure the LLDP parameters of the device globally.
Choose the menu LLDPBasic ConfigGlobal Config to load the following page.
Figure 15-1 Global Configuration
The following entries are displayed on this screen:
Global Config
LLDP:
Enable/disable LLDP function globally.
Parameters Config
Transmit Interval:
Enter the interval for the local device to transmit LLDPDU to its
neighbors. The default value is 30 seconds.
Hold Multiplier:
Enter a multiplier on the Transmit Interval. It determines the
actual TTL (Time To Live) value
used in an LLDPDU. TTL = Hold
Multiplier * Transmit Interval. The default value is 4.
Transmit Delay: Enter a value from 1 to 8192 in seconds
to specify the time for
the local device to transmit LLDPDU to its neighbors after
changes occur so as to prevent
LLDPDU being sent frequently.
The default value is 2 seconds.
Reinit Delay:
This parameter indicates the amount of delay from when LLDP
status becomes "disable" until re-
initialization will be attempted.
The default value is 3 seconds.
Notification
Interval:
Specify the interval of Trap message which will be sent from
local device to network management system.
The default value
is 5 seconds.