Business Networking Solution Installation Guide JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots T1700X-16TS
About this Installation Guide This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during the installation. This Installation Guide is structured as follows: Chapter 1 Introduction. This chapter describes the external components of the switch. Chapter 2 Installation. This chapter illustrates how to install the switch. Chapter 3 Lightning Protection. This chapter illustrates how to prevent lightning damage. Chapter 4 Connection.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Contents Chapter 1 Introduction———————————— 01 1.1 1.2 Product Overview............................................................01 Appearance........................................................................01 Chapter 2 Installation———————————— 04 2.1 Package Contents...........................................................04 2.3 Installation Tools...............................................................06 2.2 2.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 1 Introduction 1.1 Product Overview TP-Link 10-Gigabit Smart Switch provides wire-speed performance and abundant L2 and L2+ management features. It provides a variety of service features and multiple powerful functions with high security.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots LED SYS FAN Status Indication On/Off The switch is working abnormally Flashing Green Link/Act (Port 1-12) Not all the fans work properly Off Yellow Off Green Link/Act (Port 13-16) All the fans work properly Yellow Green Yellow Off The switch is working normally The switch is working abnormally On There is a 10Gbps device connected to the corresponding port but no activity Flashing Data is being transmitted or received On Ther
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots ■■ Rear Panel The rear panel of T1700X-16TS is shown as the following figure. Figure 1-2 Rear Panel of T1700X-16TS Kensington Security Slot Grounding Terminal Power Socket Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen. Grounding Terminal The switch already comes with lightning protection mechanism.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 2 Installation 2.1 Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Switch One Power Cord This Installation Guide Business Networking Solution Installation Guide Two mounting brackets, eight screws and four feet 2.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots ■■ Site Requirements Temperature/Humidity 40℃ 0℃ Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken. ■■ ■■ ■■ ■■ Ensure the rack and device are well earthed. Make sure the power socket has a good contact with the ground.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots 2.4 Product Installation ■■ Desktop Installation To install the device on the desktop, please follow the steps: 1. Set the device on a flat surface strong enough to support the entire weight of the device with all fittings. 2. Remove the adhesive backing papers from the rubber feet. 3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots 3. After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure. Figure 2-3 Rack Installation Rack Caution: Please set 5 to 10cm gaps around the device for air circulation. Please avoid any heavy thing placed on the device.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 3 Lightning Protection 3.1 Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. Note: It's not recommended using Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots ■■ Requirements for Cabling Indoors When cabling indoors, keep a certain distance away from the devices that may cause high-frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor. ■■ ■■ The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the loop area formed by the cable itself as small as possible.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Cable 2 to 5kVA powerline >5kVA powerline Parallel cabling One is in the grounded metal raceway or metal pipe The both are in the grounded metal raceway or metal pipe 300 150 80 Parallel cabling 600 The both are in the grounded metal raceway or metal pipe 150 One is in the grounded metal raceway or metal pipe Device Min Distance (m) Transformer room 2.00 Switch case Elevator tower Air-conditioner room 3.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Figure 3-1 Connecting to the Ground Switch (Rear Panel) AC Power Cord (with PE cable) Note: The figure is to illustrate the application and principle. The power plug you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Equipotential Bonding Equipotential Bonding is the practice of intentionally electrically connecting all earthed systems to the same grounding grid or connecting the grounding grids of all the earthed systems together through the ground or overground metal so as to create an earthed equipotential zone.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Note: Power lightning arrester is not provided with our product. If needed, please self purchase it. Signal lightning arrester is used to protect RJ45 ports of the device from lightning. When cabling outdoors, please install a signal lightning arrester before connecting the cable to the device.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 4 Connection 4.1 Ethernet Port Connect a Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. Figure 4-1 Connecting the RJ45 Port RJ45 Port 4.2 RJ45 Cable SFP+ Port Connect an SFP/SFP+ transceiver or an SFP+ cable to the SFP+ port. Make sure the SFP+ module minimum bend radius is met when using the SFP+ cable. The SFP+ ports support 10G connection by default.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots ■■ ■■ 4.4 The power socket, device and rack are well grounded. The device is correctly connected to other network devices. Power On Plug in the negative connector of the provided power cord into the power socket of the device, and the positive connector into a power outlet as the following figure shows. Figure 4-3 Connecting to Power Supply 2 1 Note: The figure is to illustrate the application and principle.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 5 Configuration 5.1 Configure the Switch via GUI 1. To access the GUI of the switch, open a web browser and t ype the default management address http://192.168.0.1 in the address field of the browser, then press the Enter key. Figure 5-1 Web Browser Note: To log on to the GUI of the switch, the IP address of your PC should be set in the same subnet addresses of the switch. The IP address is 192.168.0.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots 3. After a successful login, the main page will appear as the following figure, and you can configure the function by clicking the setup menu on the left side of the screen. Figure 5-3 5.2 Main Page of the Switch Configure the Switch Using CLI You can log on to the switch and access the CLI by Logging on to the switch remotely by a Telnet connection through an Ethernet port.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots 3. Type telnet 192.168.0.1 in the command prompt shown as Figure 5-5, and press the Enter button. Figure 5-5 Connecting to the Switch 4. Type the default user name and password (both of them are admin), then press the Enter button so as to enter User EXEC Mode. Figure 5-6 Enter into the User EXEC Mode For detailed CLI configuration instructions, please refer to the CLI Reference Guide on the resource CD.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? Press the Reset button for at least 5 seconds to reset the system. The system will be reset to the factory default settings, and the default login user name and password are both admin. Q2. Why does the PWR LED work abnormally? The PWR LED should be lit up when the power system works normally.
JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Appendix B Specifications Item Content Standards IEEE802.3u, IEEE802.3ab, IEEE802.3ad, IEEE802.3ae, IEEE802.3an, IEEE802.3z, IEEE802.3x, IEEE802.1ab, IEEE802.1p, IEEE802.1q, IEEE802.1x, IEEE802.1d, IEEE802.1s, IEEE802.1w Transmission Medium Transfer Method 100Base-TX 2-pair UTP/STP of Cat. 5 or above (maximum 100m) 1000Base-T 4-pair UTP/STP of Cat. 5e and Cat.
FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
BSMI Notice 安全諮詢及注意事項 • 請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。 • 清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。 • 注意防潮,請勿將水或其他液體潑灑到本產品上。 • 插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口。 • 請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。 • 請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。 此為甲類資訊技術設備,于居住環境中使用時,可能會造成射頻擾動,在此種情況下,使用者會被要求採取某些適 當的對策。 限用物質含有情況標示聲明書 限用物質及其化學符號 產品元件名稱 PCB 外殼 鉛 Pb 鎘 Cd 汞 Hg 六價鉻 CrVI 多溴聯苯 PBB 多溴二苯醚 PBDE ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 備考1. "超出0.1 wt %" 及 "超出0.01 wt %" 系指限用物質之百分比含量超出百分比含量基準值。 備考2.
For technical support and other information, please visit http://www.tp-link.com/support, or simply scan the QR code. The products of TP-Link partly contain software code developed by third parties, including software code subject to the GNU General Public License (“GPL”). As applicable, the terms of the GPL and any information on obtaining access to the respective GPL Code used in TP-Link products are available to you in GPL-Code-Centre under (http://www.tp-link.com/en/support/gpl/).