User manual
Technical Data
TowiTek Mini alarm module
Dimensions: 50 x 51 x 22 mm
Stromversorgung: 9-12V~(AC) or
12-15V= (DC)
@ 60mA max.
Rating for relay contact: 250VAC / 5A
Allowed environment temp.: 0°C .... 40°C (no condensing water)
Alarm duration: 5...120 seconds
Entry / exit delay 0 ... 30 seconds
Disposal after end of using life for this product
Electronic devices of all kinds must not be disposed thru regular
household waste disposal but should be turned in to a collection
point for proper recycling. Please check with your local
requirements.
Limited Warranty
This product was designed and manufactured with great care and comes with a
warranty against material or manufacturing defects at time of purchase. This
warranty is valid for 24 months starting with the day of purchase and can be claimed
with original sales receipt. The warraty of TowiTek is limited to cost free repairing or
replacement of the defective unit. Expenses and risk of transportation; compensation
for installation and de-installation and all other expenses which may be related to the
repair or exchange of this product are not refunded by TowiTek. The liability for
consequential damages resulting from
TowiTek
Mini Alarm Module
Nr. 19 12 66
User Guide
www.conrad.com
Thank you for purchasing this product of TowiTek!
This user guide contains many important instructions for
the safe and proper use of this product. The purpose of this
user guide is to make sure you will always get best
performance and reliable operation of your new product.
PLEASE FULLY READ THIS USER GUIDE!
The handling of products operating with electric current requires you to
follow the rules from VDE such as VDE 0100, VDE0550/0551, VDE 0700,
VDE 0711 and VDE 0860 or other local rules in your country.
•
TowiTek modules are not designed and authorized for use in life support
or life saving applications! Do not use the product for applications in
which a temporary or permanent failure or malfunction could cause
damage to persons or propery.
•
If the module is used to switch currents greater 24V it is necessary to
have the installation done with no voltage applied and performed by a
trained professional authorized for such work. The module may only be
used in such application if it was installed in a safe to touch enclosure.
•
The module must only be used in dry and clean environment. The use
near water, heavy dirt and/or high humidity is dangerous and not
permitted.
•
The product must not be used in conjunction with any type of flammable
liquid or gas or other environment with risk of spark triggered
explosions.
•
Never exceed the limits or ratings listed in the 'Technical Data' section at
the end of this user guide.
•
If the module is used in schools or educational facilities or similar
institutions the operation must be supervised by trained and authorized
staff.
•
The product itself and all parts thereof (including packing material) are
not suitable toys for childern! (choking hazard, risk of electric shock, ...)
Intended use for this product
The TowiTek Mini Alarm Module is a compact size alarm system based on
microcontroller technology. Its well thought features allow it to be used in
many applications.
Features of the
Mini Alarm Module
•
Connection of two signalling loops (with / without delay)
•
Entry and exit delay on input loop #1, configurable 0 ... 30 seconds
•
Alarm duration configurable from 5..120 seconds
•
Alarm inputs can work with 'normally open' or 'normally closed' sensors
•
Alarm inputs can work with loop resistance supervision
•
Digital signal processing with microcontroller using analog/digital
conversion for loop resistance checking
Operation instructions
Learning the normal (quiet) condition for input lines
The Mini alarm module has connections for two signalling loops with two
contacts each. There are various configurations possible:
•
The contacts are not connected in quiet state and connecting the
contacts will trigger the alarm (normally open mode)
•
The contacts are connected in quiet state and disconnection of the
contacts will trigger the alarm (normally closed mode)
•
The contacts are connected with an resistor (recommendation 2k Ohm).
Both attempts of manipulation, disconnection and short circuit of the
contacts would trigger an alarm if this mode is used.
Both alarm inputs can be used in different configuration mode if desired.