Time Bucket mode 1:
The luminance of the light changes with the time bucket. The internal timer starts timing or reset with the
ambient luminance under working conditions.
The luminance is 70% in 0.5H, 0.5H-3.5H is 100%, 3.5H-4.5H is 70%, 4.5H-5.5H is 50%.Then turn off the light
when the luminance is 20% until the environment is bright.
Time Bucket mode 2:
The luminance of the light changes with the time bucket. The internal timer starts timing or reset with the
ambient luminance under working conditions.
The luminance is 70% in 0.5H, 0.5H-3.5H is 100%, 3.5H-4.5H is 70%, 4.5H-5.5H is 50%, 5.5H-10H is 20%.Then
turn off the light when the luminance is 70% until the environment is bright.
Timing mode:
1. The internal timer starts timing or reset with the ambient luminance under working conditions, Turn off the
lights after 3H
2. The internal timer starts timing or reset with the ambient luminance under working conditions, Turn off the
lights after 6H
3. The internal timer starts timing or reset with the ambient luminance under working conditions, Turn off the
lights after 9H
Cancel timing mode:
Timing mode 3H / 6H / 9H Failure.
Test button:
TEST-Press the button, the red indicator light is on, keep 10% brightness for 1S then entering the induction s
tate,after sense the movement of the object,the light brightness turn to 100%. After testing for 6S,the test mo
de is automatically exited, and the red indicator light is off.
Remark:
1. Time Bucket mode/fixed mode/microwave mode can only be activated in one mode at
the same time. Timing mode can be superimposed with Time Bucket mode/fixed mode/microwave mode,
the lights turn off when the timing time up.
2. The photocell is always active in the non-sleep state. When the ambient luminance is
dark or the infrared light is weak, the set working mode enters the active state and starts working. When
the ambient luminance is brighter or the infrared is stronger, the set working mode is disabled and the
light stops working.
3. Timing mode and Time bucket mode are not suitable for use in environments where
there is no day or night transition.
4. Remote control operation The red working indicator light and the fixture twinkle twice
The product has memory function Memory function fails after power-off in timing mode