Installation Sheet
TEST RUN
NOTE TO THE INSTALLER
PERIODIC MAINTENANCE
1. For Toilet: Sit on the toilet seat.
For Urinal: Stand within two feet from the front of the Flush Valve.
2. Stay there for 6 seconds or more and then leave the toilet seat or the urinal. The valve
will automatically flush.
3. Press the manual flushing button and make sure the valve flushes properly and the sensor
red light of the sensor is on for 2 seconds.
4. Recheck all the pipe connections for water leaks. If the Flush Valve is not operating
properly following the test run consult the Troubleshooting section on p.12.
After the Flush Valve unit has been installed correctly, please explain to your customer how to
use it and tell them to observe the following instructions:
1. Do not put any object in front of the sensor window which could obstruct the sensor,
causing it to malfunction.
2. In case of any trouble, consult the troubleshooting section on p.12. If you lack the
necessary skills required or have difficulty following the directions for installation,
maintenance, repairs, troubleshooting or adjustments of the product, do not proceed
without help from a qualified person to assist you.
Please check your EcoPower Flush Valve at least once a month according to the
following instructions to avoid risk of property damage.
Check the piping to see whether there is any leakage.
Press the manual flushing button and make sure the sensor red light is on for 2
seconds to see if the generator performs properly
or not.
If the red light is not on, check the generator to see
if any debris is clogged up at the turbine.
ENGLISH
10