Installation Guide
SPECIFICATIONS
• Water Use 1.28 GPF/4.8LPF
• Flush System Tornado Flush
TM
• Min. Water Pressure 8 psi (flowing)
• Water Surface 7-1/8" x 9-1/8"
• Trap Diameter 2-1/8"
• Rough-in 12"
• Trap Seal 2-1/8"
• Warranty One Year Limited Warranty
• Material Vitreous china
• Shipping Weight CST634CEFGT20 104lbs.
SW584T20 13.5lbs.
• Shipping Dimensions CST634CEFGT20
29-1/2" L x 18"W
x 19-1/4" H
1
x 27-1/8" H
2
SW584T20
23"X 19-1/4" X 5-1/2"
• See Spec sheet SW584T20 for Washlet details
MS634584CEFG
Supreme
®
II Connect+™ Toilet, 1.28GPF with Washlet
®
S350e Connect+
SS-01138 v.02
Ph: (888) 295-8134 | Fax: (800) 699-4889 | www.totousa.com | © TOTO USA
INSTALLATION NOTES
Back-to-Back Toilet Installations:
TOTO recommends the use of a nationally listed,
double sanitary tee-wye only, in vertical waste stacks,
in accordance with the stipulations noted in the
majority of nationally recognized plumbing codes.
These dimensions and specications are subject to change without notice
Double Sanitary Tee / Sanitary CrossDouble Combination Wye / 1/8 Bend
YES NO
Important Note:
Back-to-Back Toilet Installations:
TOTO USA, Inc. recommends the use
of a nationally listed, double sanitary
tee-wye only, in vertical waste stacks,
in accordance with the stipulations noted
in the majority of nationally recognized
plumbing codes.
!
12" (305mm)
*8" (203mm)
9-13/16"
(249mm)
*6" (152mm)
17-3/8"
(441mm)
25-9/16"
(650mm)
28-5/16" (720mm)
3/4" (19mm)
17-1/2" (445mm)
5-1/2" (140mm)
*SUGGESTED
DIMENSIONS
4 1/2
[117mm]
2 3/8
Diameter
12" (305mm)
*8" (203mm)
9-13/16"
(249mm)
*6" (152mm)
17-3/8"
(441mm)
25-9/16"
(650mm)
28-5/16" (720mm)
3/4" (19mm)
17-1/2" (445mm)
5-1/2" (140mm)
*SUGGESTED
DIMENSIONS
4 1/2
[117mm]
2 3/8
Diameter
* The 3-prong cord on the Washlet is on
the left side and is 3' long. The GFCI outlet
needs to have 120V, 10amps.
* GFCI Outlet
Min. 12” off floor
15-5/16"
(389mm)
18-7/8" (480mm)
(Round)
20-3/4" (529mm)
(Elongated)
3-15/16"
(100mm)
3/8"
(10mm)
1-5/8"
(42mm)
5-1/2"
(140mm)
7-1/16"
(180mm)
2-1/2"
(63mm)
7/8"
(22mm)
* The 3-prong cord on the Washlet is on
the left side and is 3' long. The GFCI outlet
needs to have 120V, 10amps.
* GFCI Outlet
Min. 12” off floor
15-5/16"
(389mm)
18-7/8" (480mm)
(Round)
20-3/4" (529mm)
(Elongated)
3-15/16"
(100mm)
3/8"
(10mm)
1-5/8"
(42mm)
5-1/2"
(140mm)
7-1/16"
(180mm)
2-1/2"
(63mm)
7/8"
(22mm)