Spec Sheet
Model:
TU48HFI
U-MATCH
Job Name:
Schedule Reference: Date:
Specification are subject to change without notice.
48,000 BTUH Slim Duct Heat Pump System
Item Unit Specification
ODU Model
-
TU48H3O
IDU Model
-
TU48HFI
Cooling Capacity Btu/h 48,000
Heating Capacity (47°F) Btu/h 54,500
Heating Capacity (17°F) Btu/h 30,600
Cooling Capacity Range Btu/h 20,400-49,500
Heating Capacity Range Btu/h 17,500-58,000
Cooling Power Input (Max) W 5,600
Heating Power Input (Max) W 5,500
SEER
-
16.0
HSPF
-
9.0
EER
W/W
9.3
COP
W/W
3.1
Cooling Operation Range
℉(℃)
0~118.0 (–18.0~48.0)
Heating Operation Range
℉(℃)
0~75.0(–18.
0~24.0)
Gas Pipe Size (OD) Inch 5/8
Liquid Pipe Size (OD) Inch 3/8
Connection Method
-
Flared
Factory Charge oz 140.8
Additional Charge oz/ft 0.6
Pre-Charge Length ft. 25
MAX Refrigerant Pipe Length ft. 230
Min Refrigerant Pipe Length ft. 10
MAX Refrigerant Pipe Elevation ft. 49
Air Flow Volume (Cooling Wet)(Lo/Hi) CFM 900/1470
Air Flow Volume (Heating Dry)(Lo/Hi) CFM 900/1470
Sound Pressure Level (Min/Max) dB(A) 41/53
Dehumidicatio
n pt/hr 1.80
Condensate Drain Lift (Height) in 33
Power Supply
-
208/230 V, 1 Phase, 60 Hz
Min/Max Voltage V 187 - 253
MCA/ Power Cable Size A 5.0
MOCP/Breaker Size A 15
Communication Wire Size
-
18-2 AWG / 300V THHN
Compressor Type
-
DC Inverter Driven Rotary
Compressor RLA A 35.5
Refrigerant Type
-
R410A
Fan Motor Power Output HP 2 x 1/6
Fan Motor FLA A 2 x 2.0
Sound Pressure Level(Cooling/Heating) dB(A) 59/59
Power Supply
-
208/23
0 V, 1 Phase, 60 Hz
Min/Max Voltage V 187 - 253
Power Supply Wire Size
-
8-3 AWG
MCA/ Power Cable Size A 45.0
MOCP/Breaker Size A 70
System Ratings
Indoor Unit Data
Outdoor Unit Data