Submittal
OPERATIONAL PERFORMANCE SPECIFICATIONS
TM42H3O
Indoor Units
Combinations
Rated
System
Indoor
Unit A
Indoor
Unit B
Indoor
Unit C
Indoor
Unit D
Indoor
Unit E
(BtuH) (BtuH) (BtuH) (BtuH) (BtuH) (BtuH)
9+9 32,500 9,500 9,500 NA NA NA
9+12 35,500 9,500 13,000 NA NA NA
9+18 46,300 9,300 18,500 NA NA NA
9+24 51,200 8,000 21,600 NA NA NA
12+12 39,000 13,000 13,000 NA NA NA
12+18 47,000 12,000 17,500 NA NA NA
12+24 58,400 11,200 23,600 NA NA NA
18+18 52,000 17,400 17,300 NA NA NA
18+24 59,400 16,200 21,600 NA NA NA
24+24 57,600 19,200 19,200 NA NA NA
9+9+9 36,000 9,000 9,000 9,000 NA NA
9+9+12 37,800 9,000 9,000 10,800 NA NA
9+9+18 43,800 8,800 8,800 17,400 NA NA
9+9+24 47,500 7,900 7,900 23,800 NA NA
9+12+12 45,000 9,000 12,000 12,000 NA NA
9+12+18 47,350 8,650 11,200 16,300 NA NA
9+12+24 51,180 7,900 10,240 22,800 NA NA
9+18+18 57,750 7,560 16,730 16,730 NA NA
12+12+12 48,000 12,000 12,000 12,000 NA NA
12+12+18 51,500 11,400 11,400 17,300 NA NA
12+12+24 53,120 10,620 10,620 21,260 NA NA
12+18+18 58,685 10,130 16,185 16,185 NA NA
9+9+9+9 55,000 11,000 11,000 11,000 11,000 NA
9+9+9+12 54,460 10,260 10,260 10,260 13,420 NA
9+9+9+18 53,880 8,920 8,920 8,920 18,200 NA
9+9+12+12 54,630 9,630 9,630 12,870 12,870 NA
9+9+12+18 54,150 8,550 8,550 11,400 17,100 NA
9+12+12+12 57,680 8,120 12,390 12,390 12,390 NA
9+12+12+18 56,250 8,010 10,680 10,680 16,200 NA
12+12+12+12 57,350 11,470 11,470 11,470 11,470 NA
9+9+9+9+9 54,600 9,100 9,100 9,100 9,100 9,100
9+9+9+9+12 54,180 8,540 8,540 8,540 8,540 11,480
Note:
1) It is critical to size the outdoor unit for the entire building load and each indoor unit for it's individual zone load.
Cooling Nominal Test Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB
HEATING CAPACITY (BTUH)
Specifications are subject to change without notice. Manufacturer reserves the right to discontinue or modify specifications or designs
without notice or without incurring obligations. All rights reserved.
All Rights Reserved
TOSOT Comfort 2017