Submittal
OPERATIONAL PERFORMANCE SPECIFICATIONS
TM36H4O
Indoor Units
Combinations
Rated System
Capacity
Indoor
Unit A
Indoor
Unit B
Indoor
Unit C
Indoor
Unit D
Indoor
Unit E
(BtuH) (BtuH) (BtuH) (BtuH) (BtuH) (BtuH)
9+9
19,000 9,500 9,500 NA NA NA
9+12
22,500 9,500 13,000 NA NA NA
9+18
27,800 9,300 18,500 NA NA NA
9+24
29,600 8,000 21,600 NA NA NA
12+12
26,000 13,000 13,000 NA NA NA
12+18
29,500 12,000 17,500 NA NA NA
12+24
33,200 11,200 22,000 NA NA NA
18+18
35,000 17,500 17,500 NA NA NA
18+24
36,000 15,000 21,000 NA NA NA
24+24
38,000 19,000 19,000 NA NA NA
9+9+9
27,000 9,000 9,000 9,000 NA NA
9+9+12
28,800 9,000 9,000 10,800 NA NA
9+9+18
35,000
8,800 8,800 17,400 NA NA
9+9+24
36,600 7,800 7,800 21,000 NA NA
9+12+12
33,000 9,000 12,000 12,000 NA NA
9+12+18
35,150 8,650 11,200 15,300 NA NA
9+12+24
37,640 7,900 9,240 20,500 NA NA
9+18+18
37,960 7,560 15,200 15,200 NA NA
12+12+12
36,000 12,000 12,000 12,000 NA NA
12+12+18
37,200 10,600 10,600 16,000 NA NA
12+12+24
38,000 9,500 9,500 19,000 NA NA
12+18+18
38,300 9,300 14,500 14,500 NA NA
9+9+9+9
42,000 10,500 10,500 10,500 10,500 NA
9+9+9+12
42,000 9,600 9,600 9,600 13,200 NA
9+9+9+18
41,940
8,400 8,400 8,400 16,740
NA
9+9+12+12
42,000
9,000 9,000 12,000 12,000
NA
9+9+12+18
42,680
8,000 8,000 10,680 16,000
NA
9+12+12+12
40,800
8,100 10,900 10,900 10,900
NA
12+12+12+12
42,720
10,680 10,680 10,680 10,680
NA
9+9+9+9+9
42,750
8,550 8,550 8,550 8,550 8,550
9+9+9+9+12
42,240
7,920 7,920 7,920 7,920 10,560
Note:
1) It is critical to size the outdoor unit for the entire building load and each indoor unit for it's individual zone load.
HEATING CAPACITY (BTUH)
Specifications are subject to change without notice. Manufacturer reserves the right to discontinue or modify specifications or designs