Instruction Manual
  E6581301 
F-86 
6
■ Communication parameters (4-wire RS485) 
These parameters allow you to change the communication speed, parity, inverter number, communication error trip 
timer setting, etc. from the operation panel or an external control device. 
Title  Function  Adjustment range  Default setting
H
Inverter number (common)  ~ 
H
Communications time-out time 
(common to 2-wire RS485 and 4-wire 
RS485) 
:OFF 
~ sec. 
H
Communications time-out action * 
(common to 2-wire RS485 and 4-wire 
RS485) 
Setting 
2-wire 
RS485 
4-wire 
RS485 
 No action No action
 Alarm  No action
 Trip  No action
 No action Alarm 
 Alarm  Alarm 
 Trip  Alarm 
 No action Trip 
 Alarm  Trip 
 Trip  Trip 
H
Communication1 time-out condition selection
:Disconnection detection 
:When communication mode 
enable 
:1+Driving operation 
H
Frequency point selection 
:Disabled 
:2-wire RS485 
:4-wire RS485 
:Communication add option 
H
Point 1 setting  ~ %  
H
Point 1 frequency  ~HJ Hz  
H
Point 2 setting  ~ %  
H
Point 2 frequency  ~HJ Hz 
Inverter with a 
model number 
ending with 
–WN, HN: 
-WP: 
H
Communication speed (4-wire RS485) 
:9600 bps, :19200 bps, 
:38400 bps 
H
Send waiting time (4-wire RS485)  :Default, ~ sec.  
H
Inverter-to-inverter communication setting
(4-wire RS485) 
:Slave (issues a 0Hz command if 
something goes wrong with the 
master) 
:Slave (continues operation if 
something goes wrong with the 
master) 
:Slave (trips for emergency stop if 
something goes wrong with the 
master) 
:Master (sends a frequency 
command) 
:Master (sends an output frequency)
:Master (sends a torque command) 
:Master (sends an output torque 
command) 
H
Parity 
(2-wire RS485) 
:Non parity 
:Even parity 
:Odd parity
H
Protocol selection (4-wire RS485) 
:TOSHIBA 
:MODBUS 