"The cooling fan automatically operates whenever the ambient temperature is high, even when the inverter is out of 
operation. 
Title  Function  Adjustment range  Default setting 
H Cooling fan control selection  :Auto, :Always ON  
6.33.12  Cumulative  operation time  alarm  setting!
!!
!
H
HH
H    : Cumulative operation time alarm setting 
• Function 
This parameter is to make a setting so that the inverter puts out a signal when its cumulative operation time 
has reached the time set with 
H
. 
* Indication of  represents 10 hours. Ex.: If  is displayed, the cumulative operation time is 3850 hours. 
Title  Function  Adjustment range  Default setting 
H Cumulative operation time alarm setting  ~ 
■
 Setting of output signal 
Ex.) When assigning the cumulative operation alarm signal output function to the OUT2 terminal 
Title  Function  Adjustment range  Example of setting 
H  Output terminal function selection 2 (OUT2)  ~  (Negative logic )
6.33.13 Abnormal  speed  detection!
!!
!
H
HH
H    : Abnormal speed detection time 
H
HH
H    : Overspeed detection frequency upper band 
H
HH
H    : Overspeed detection frequency lower band 
• Function 
When use at speed control mode with sensor (
RV
=
, 
), it always monitors the rotational speed of the 
motor, even when the motor is at rest, and if the speed remains out of the specified limits for the specified 
length of time, it outputs an error signal. 
When use at speed control mode without sensor (
RV
=
~
), it always monitors the estimated rotational 
speed of the motor. 
Title  Function  Adjustment range  Default setting 
H Abnormal speed detection time  ~ sec.  
H Overspeed detection frequency upper band : Disabled, ~
ҏ
Hz  
H Overspeed detection frequency lower band : Disabled, ~
ҏ
Hz  
Output frequency [Hz]
Time [s]
0
Output frequency 
G
 trip
H
H
H
H
Note 1: This function doesn't operate at the time of a torque control. 
!
Note 2: It is advisable to set the parameter H (Acceleration/deceleration operation after torque limit) to  when 
this function is set. 