Instruction Manual
E6581364 
4 
1.2. Standard connection diagram (Star-delta switching start) 
This is the circuit to switch the motor to commercial power supply Star Delta (star-delta) connection 
startup when the inverter’s protective function is activated.
FL
G / E
F 
RES
CC
R/L1 
S/L2 
T/L3 
U/T1
V/T2
W/T3
FLC 
FLB 
FLA
S1
ST
R 
S2
S3
OUT2 
P24/PLC 
OUT1 
RY2 
PO 
PB
PC/- 
PA/+
Main circuit 
MCCB 
I M
RY1
MC3 
*2
MC2 
*3
MC1 
*2
MCY
MCD
For motor protection
 THR 
*4
Motor
Run 
command 
Stand-by 
*7
Reset 
*6
Emergency 
stop 
*5 
Protective action 
detection
 relay 
Common 
+SU 
Control 
circuit
CCA
RX
VI/II 
RR/S4
PP
A
M
FM 
OUT1 
NO 
CC 
*1: The control power supply backup option (Model: CPS002Z) is needed.
*2: Observe the Item 1 in 1.3, “Precautions.”
*3: See Item 2 in 1.3, “Precautions.” 
*4: Be careful about Items 3 in 1.3, “Precautions.” 
*5:
 Be careful about Items 5 and 7 in 1.3, “Precautions.” 
*6: Be careful about Item 6 in 1.3, “Precautions.
Control power supply 
backup option 
*1
*7: VF-AS1's 'WP1/WN1' model and VF-PS1 don't have 'ST' 
terminal. Please set next parameter for use 'S3' terminal as 
'ST' function. 
f110 (Always ON function selection 1)    = 0 
  f117 (Input terminal function selection: S3)    = 6 