Datasheet

Outdoor unit
Indoor unit
RAS-10G2AVP-E
RAS-10G2KVP-E
RAS-13G2AVP-E
RAS-13G2KVP-E
RAS-16G2AVP-E
RAS-16G2KVP-E
Cooling capacity kW 2,50 3,50 4,50
Cooling range (min. - max.) kW 0,55 - 3,5 0,63 - 4,1 0,63 - 5,0
Power input (min. - rated - max.) kW C 0,11 - 0,485 - 0,9 0,17 - 0,82 - 1,20 0,17 - 1,30 - 1,75
EER W/W 5,15 4,27 3,46
SEER 9,10 8,90 7,30
Energy efficiency class C A+++ A+++ A++
Seasonal electricity consumption kWh/a C 96 138 216
Annual energy consumption kWh 243 410 650
Heating capacity kW 3,2 4,0 5,5
Heating range (min. - max.) kW 0,45 - 5,8 0,65 - 6,3 0,65 - 6,8
Power input (min. - rated - max.) kW H 0,09 - 0,58 - 1,65 0,14- 0,80 - 1,77 0,14 - 1,37 - 2,05
COP W/W 5,52 5,00 4,01
SCOP (Average) 5,20 5,10 4,60
Energy efficiency class (Average) H A+++ A+++ A++
Seasonal electricity consumption kWh/a H 808 988 1369
G2AVP +G2KVP
Performance data
Indoor unit RAS-10G2KVP-E RAS-13G2KVP-E RAS-16G2KVP-E
Air Flow (max) m
3
/h - l/s C 648 - 180 672 -187 696 - 193
Sound pressure level (h/l (q)) dB(A) C 42/24 (20) 43/25 (21) 44/26 (23)
Sound power level (h) dB(A) C 57 58 59
Air Flow (max) m
3
/h - l/s H 678 - 188 726 - 202 744 - 207
Sound pressure level (h/l (q)) dB(A) H 43/24 (20) 44/25 (21) 45/26 (23)
Sound power level (h) dB(A) H 58 59 60
Dimensions (HxWxD) mm 293x831x270 293x831x270 293x831x270
Weight kg 14 14 14
G2KVP
Physical data Indoor unit
Outdoor unit RAS-10G2AVP-E RAS-13G2AVP-E RAS-16G2AVP-E
Air Flow m
3
/h - l/s C 1872 - 520 2160 - 600 2544 - 707
Sound pressure level dB(A) C 46 48 49
Sound power level dB(A) C 61 63 64
Operating range °C C -10~46 -10~46 -10~46
Air Flow m
3
/h - l/s H 1872 - 520 2160 -600 2544 - 707
Sound pressure level (h) dB(A) H 47 49 50
Sound power level (h) dBA H 62 64 65
Operating range °C H -15~24 -15~24 -15~24
Dimensions (HxWxD) mm 630x800x300 630x800x300 630x800x300
Weight kg 42 42 42
Compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary
Flare connections (gas-liquid) 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Minimum pipe length m 2 2 2
Maximum pipe length m 25 25 25
Maximum height difference m 10 10 10
Chargeless pipe length m 15 15 15
Power supply V-ph-Hz 220/240-1-50, 220/230-1-60 220/240-1-50, 220/230-1-60 220/240-1-50, 220/230-1-60
G2AVP
Physical data Outdoor unit
TOSHIBA | 15
C = cooling mode
H = heating mode
h/l (q)= high / low speed (quiet)