Full Product Manual

Page 12 User Manual
WATER DRAINAGE cont.
For Heat Pump models, remove the middle drain plug from the
back of the unit and install the drain connector (5/8” universal
female adapter) with a 3/4“ hose (not included). For models
without the drain connector, attach the drain hose to the
connector. Place the end of the hose in the drain area you’re using.
Operating
Instructions
When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times. The digital
display shows “P1.” At this time the air conditioning/
dehumidi cation process will immediately stop. However, the
fan motor will continue to operate (this is normal). Carefully
move the unit to a drain location, remove the bottom drain
plug and let the water drain away. Reinstall the bottom drain
plug and restart the machine until the “P1” symbol disappears.
If the error repeats, call for service.
NOTICE
Be sure to reinstall the bottom drain plug  rmly to prevent
leakage before using the unit.
NOTICE
In Heat Pump mode, the drain hose can be elevated up to 6ft (1.8m).
Direct the hose toward the drain, making sure that there are no
kinks that will re strict water ow. Place the end of the hose into the
drain and make sure the end of the hose is directed downward
manufacturer. See Figs with ).
Figures with
X
are installation not recommended by the
manufacturer. When the continuous drain hose is not used,
ensure that the corresponding drain plug and knob are installed
rmly to prevent leaks.
¥
Drain hose
adaptor
Continuous
drain hose
Remove the
middle drain
plug
Units with
heat pump
model only
X
Drain hose
adaptor
Press the power
cord buckle into
the rear cover.
Drain
hose
adaptor
¥
Delivery lift < 6ft
Units with heat pump model only