Operation Manual

4. DIAGNOSTIC TEST OPERATION
EO18-11004A
4.9 Conventional RAM Read/Write Test
4- 8
4.9 Conventional RAM Read/Write Test
CAUTION!
When this test is completed, RAM clear is performed which deletes all programmed data and sales
data stored in the memory of the ECR. (i.e., the ECR goes back to initial status.)
(1) Contents
The Conventional RAM (1M bit) is checked.
This test is repeated until the [CPN] key (for MA-1535)/[AT/TL] key (for FS-1535) in default key
layout is depressed.
(2) Operation
Control Lock: BLIND
8011 [AT/TL]
(3) Print Sample
NOTES: 1. Depressing the [CPN] key (for MA-1535)/[AT/TL] key (for FS-1535) in default key layout
will issue a receipt, resulting that this test is completed. At this time, RAM clear is
performed.
2. Every 10 times of this test, Date, Time, and Frequency of the test are printed on a
receipt.
Depressing the [CPN] key (for MA-1535)/[AT/TL] key (for FS-1535) in default key layout
will print Date, Time, and Frequency of the test as of this time, resulting that this test is
completed.
Every 10 times of this test, Date, Time, and Frequency of the test are printed.
As of the end of this test, Date, Time, and Frequency of the test are printed.