Operation Manual

4. DIAGNOSTIC TEST OPERATION
EO18-11004A
4.2 Display Test
4- 2
4.2 Display Test
(1) Contents
The conditions of both the 7-segment Display (the numeric display row) and the Alphanumeric
Display (the upper row) are tested so that the segment and the digit are lit one by one.
(2) Operation
Control Lock: BLIND
8002 [AT/TL]
(3) Procedure
1) Each segment in the above displays is lit in turn.
2) Each digit is lit in the order from left to right.
3) All digits are lit.
4) The Steps 1) to 3) are repeated.
NOTES: 1. The same contents are displayed in both the Customer Display and in the Operator
Display.
2. Depressing the [CPN] key (for MA-1535)/[AT/TL] key (for FS-1535) in default key layout
will perform printing in case of OK. Depressing the [Department 26] key (for MA-
1535)/[MENU 2] key (for FS-1535) in default key layout will perform printing in case of
NG. After printing, this test is terminated. (Regarding default key layout, please refer to
Section 4.12 Default Key Layout.)
OK NG