Datasheet
278
Fiber-Optic Devices (TOSLINK
TM
)
Fiber-Optic Modules (simplex type)
Fiber-Optic Transmitting
Module
Fiber-Optic Receiving
Module
Data Rate
(b/s, NRZ)
Transmission
Distance
(m)
(1)
max
Emission
Wavelength
(nm)
(1)
Pulse Width
Distortion
(ns)
(1)
Operating
Temperature
(°C)
Compatible Optical Fiber
(
µ
m)
Compatible Optical Fiber with Fiber-Optic Connectors
(8)
TOTX111 TORX111
(2)
DC to 6M 10 670
±
55
−
20 to 70 APF (980/1000)
TOFC100-
1000 PCF (200/300)
TOCP100Q-
B/TOCP100X-
B
TOTX170
(3)
TORX170
DC to 6M
800
800
±
55
−
40 to 70
H-PCF (200/230)
CF-1071 Series
(12)
TOTX170A
(3)
TORX170
DC to 6M 40 650
±
55
−
40 to 70 APF (980/1000)
TOCP100-
B/TOCP100P-
B
TOCP155-
B/TOCP155P-
B
TOTX173 TORX173
DC to 6M 10 660
±
20
−
20 to 70
TOTX176
(7)
TORX176
(7)
DC to 6M 10 660
±
20
−
20 to 70
TOTX178A
(7)
TORX178A
(7)
0.1 to 6M 5 660
±
30
−
20 to 70
TOTX178S TORX178S
0.1 to 6M 5 660
±
30
−
20 to 70
TOTX179
(7)
TORX179
(7)
0.1 to 12M 5 650
±
25
−
20 to 70
TOTX179P TORX179P
0.1 to 12.8M 5 650
±
25
−
20 to 70
TOTX179L
(7) (13) (14)
TORX179L
(7) (13) (14)
0.1 to 12.8M 5 650
±
25
−
20 to 70
TOTX179PL
(13) (14)
TORX179PL
(13) (14)
0.1 to 12.8M 5 650
±
25
−
20 to 70
TOTX179S TORX179S
0.1 to 12.8M 5 650
±
25
−
20 to 70
TOTX140
(7) (10)
TORX178B
(7)
0.1 to 6M 5 660
±
30
−
20 to 70
TOTX141
(7) (10)
TORX141
(7) (10)
0.1 to 15M 10 650
±
25
−
20 to 70
TOTX141P
(10)
TORX141P
(10)
0.1 to 15M 10 650
±
25
−
20 to 70
TOTX141L
(7) (10) (13) (14)
TORX141L
(7) (10) (13) (14)
0.1 to 15M 10 650
±
25
−
20 to 70
TOTX141PL
(10) (13) (14)
TORX141PL
(10) (13) (14)
0.1 to 15M 10 650
±
25
−
20 to 70
APF (970/1000)
APF (980/1000)
TOCP172-
B
1000 PCF (200/300)
TOCP100Q-
B/TOCP100X-
B
TOTX180
(3)(9)
TORX180
(9)
DC to 6M
800
800
±
55
−
40 to 85
H-PCF (200/230)
CF-1071 Series
(12)
1000 PCF (200/300)
TOCP100Q-
B/TOCP100X-
B
TOTX180
(9)
TORX186
(9)
DC to 8M
700
800
±
42
−
40 to 85
H-PCF (200/230)
CF-1071 Series
(12)
TOTX180A
(3)(9)
TORX180
(9)
DC to 6M 40 650
±
55
−
40 to 85 APF (980/1000)
TOCP100-
B/TOCP100P-
B
TOCP155-
B/TOCP155P-
B
TOTX193 TORX193
DC to 6M 10 660
±
25
−
40 to 85
TOTX193K
(7)
TORX193K
(7)
DC to 6M 10 660
±
25
−
40 to 85
APF (980/1000)
−
1000 PCF (200/300)
TOCP100Q-
B/TOCP100X-
B
TOTX194
(3)
TORX194
DC to 10M
700
800
±
30
−
40 to 85
H-PCF (200/230)
CF-1071 Series
(12)
TOCP100-
B/TOCP100P-
B
TOTX195
(3)
TORX194
DC to 10M 50 670
±
30
−
40 to 85 APF (980/1000)
TOCP155-
B/TOCP155P-
B
1000 PCF (200/300)
TOCP100Q-
B/TOCP100X-
B
TOTX196 TORX196
DC to 6M
800
800
±
55
−
40 to 85
H-PCF (200/230)
CF-1071 Series
(12)
1000 PCF (200/300)
TOCP100Q-
B/TOCP100X-
B
TOTX196 TORX198
(2)
DC to 6M
800
800
±
55
−
40 to 85
H-PCF (200/230)
CF-1071 Series
(12)
TOTX197 TORX196
DC to 6M 40 670
±
55
−
40 to 85 APF (980/1000)
TOCP100-
B/TOCP100P-
B
TOCP155-
B/TOCP155P-
B
TOTX197 TORX198
(2)
DC to 6M 40 670
±
55
−
40 to 85 APF (980/1000)
TOCP100-
B/TOCP100P-
B
TOCP155-
B/TOCP155P-
B
TOSLINK is a registered trademark of Toshiba Corporation.
Note 1: Indicates values when Ta
=
25°C
Note 2: These fiber-optic receiving modules have analog output pins for monitoring the amount of received light.
Note 3: External resistances must be changed according to the transmission distance.
Note 7: These are panel mount type fiber-optic modules.
Note 8: -
or -
B in optical fiber names with or without fiber-optic connectors represent the optical fiber
·
s length and the unit of measurement in which the length is expressed.
The unit of length is represented by C (for cm) or M (for meters)
Note 9: These are fiber-optic modules in a ceramic package.
Note 10: V
CC
=
2.7 V
∼
3.6 V
Note 11: Under development
Note 12: Manufactured by Sumitomo Electric Industries, Ltd.
Note 13: Shutter system.
Note 14: New products.