Datasheet

264
AC Power Output (photocoupled relay) Devices
I
FT
I
TM
Safety Standards
(1)
Product No. Pin Configuration Features
Rank Max (mA) @Ta
=
40°C (Arms)
V
DRM
(V)
BVs
(Vrms)
UL TÜV VDE BSI SEMKO
10
TLP3502
IFT7 7
3
56
2
8
TLP3503
TLP3503 includes a Z.C.circuit.
Direct control up to
0.5-A
rms
load
Zero-voltage turn-on
(TLP3503)
IFT5 5
0.5
{
10
TLP3520
IFT7 7
7
9
6
11
5
4
1315
23
TLP3521
TLP3521 includes a Z.C.circuit.
Direct control up to
1.0-A
rms
load
Zero-voltage turn-on
(TLP3521)
IFT5 5
1.0
400
{
TLP3506
3
56
2
8
TLP3507
TLP3507 includes a Z.C.circuit.
Direct control up to
0.5-A
rms
load
Zero-voltage turn-on
(TLP3507)
10 0.5
{
TLP3526
7
9
6
11
5
4
1315
23
TLP3527
TLP3527 includes a Z.C.circuit.
Direct control up to
1.0-A
rms
load
Zero-voltage turn-on
(TLP3527)
10 1.0
600
{
10
IFT7 7
TLP3502A
3
56
2
8
Direct control up to
0.6-A
rms
load
IFT5 5
0.6
{
10
IFT7 7
TLP3520A
7
9
6
11
5
4
1315
23
Direct control up to
1.2-A
rms
load
IFT5 5
1.2
400
{
10
TLP3530
7
9
10
6
54
12
13
16
15
23
Two-channel type
IFT7 7
1.0
[for 1 channel]
1.4
[for 2 channels]
400
2500
{
Note 1: In the safety standard column:
Symbol
{
: Approved
Symbol
: Design which meets safety standard
Z.C.: Zero-cross
1.0
A
rms
[for 1
ch]
1.4
A
rms
[for 2
ch]