Datasheet
TLP624,TLP624−2,TLP624−4
2007-10-01
5
ΔV
F
/ ΔTa – I
F
Forward current I
F
(mA)
Forward voltage temperature
coefficient ΔV
F
/ ΔTa (mV / °C)
-2.8
-0.4
0.3
50
0.1
-0.8
-1.2
-1.6
-2.0
-2.4
0.5 1 3 5 10 30
1
I
FP
– V
FP
Pulse forward voltage V
FP
(V)
Pulse forward current I
FP
(mA)
1000
0
500
300
100
50
30
10
5
3
0.4 0.8 1.2 1.6 2.0 2.4
Pulse width ≦ 10 μs
Repetitive
Frequency = 100 Hz
T
a
= 25 °C
I
F
– T
a
Ambient temperature T
a
(°C)
Allowable forward current
I
F
(mA)
100
0
–20
80
60
40
20
0 20 40 60 80 100 120
TLP624
TLP624-2,-4
I
F
– V
F
Forward voltage V
F
(V)
Forward current I
F
(mA)
100
0.1
0.4
50
30
10
5
3
1
0.5
0.3
0.6 0.8 1.0 1.2 1.4 1.6
T
a
= 25 °C
Duty cycle ratio D
R
Allowable pulse forward current
I
FP
(mA)
I
FP
– D
R
5000
10
3
3000
1000
500
300
100
50
30
10
-
3
3 10
-
2
3 10
-
1
3 10
0
Pulse width ≦ 100 μs
T
a
= 25 °C
Ambient temperature Ta
(°C)
Allowable collector power
dissipation P
C
(mW)
P
C
– T
a
200
0
160
120
80
40
-20 0 20 40 60 80 100 120
TLP624
TLP624-2,-4