Datasheet
TLP2631
2007-10-01
2
Absolute Maximum Ratings
(no derating required up to 70°C)
Characteristic Symbol Rating Unit
Forward current (each channel) I
F
20 mA
Pulse forward current
(each channel)*
I
FP
30 mA
LED
Reverse voltage (each channel) V
R
5 V
Output current (each channel) I
O
16 mA
Output voltage (each channel) V
O
−0.5~7 V
Supply voltage
(1 minute maximum)
V
CC
7 V
Detector
Output collector power
dissipation (each channel)
P
O
40 mW
Operating temperature range T
stg
−55~125 °C
Storage temperature range T
opr
−40~85 °C
Lead soldering temperature
(10s)**
T
sol
260 °C
Isolation voltage
(AC, 1 min., R.H.≤ 60%, Note 3)
BV
S
2500 Vrms
Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even
if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings and the operating ranges.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
* t ≤ 1 msec duration.
** 2mm below seating plane.
Recommended Operating Conditions
Characteristic Symbol Min. Typ. Max. Unit
Input current, low level, each channel I
FL
0 ― 250 μA
Input current, high level, each channel I
FH
6.3* ― 20 mA
Supply voltage**, output V
CC
4.5 5 5.5 V
Fan out (TTL load, each channel) N ― ― 8
Operating temperature T
opr
0 ― 70 °C
Note: Recommended operating conditions are given as a design guideline to obtain expected performance of the
device. Additionally, each item is an independent guideline respectively. In developing designs using this
product, please confirm specified characteristics shown in this document.
*6.3mA is a guard banded value which allows for at least 20% CTR degradation.
Initial input current threshold value is 5.0mA or less.
**This item denotes operating ranges, not meaning of recommended operating conditions.