Datasheet
TLP250
2007-10-01
4
Switching Characteristics
(Ta =
−
20~70°C , unless otherwise specified)
Characteristic Symbol
Test
Cir−
cuit
Test Condition Min Typ.* Max Unit
L→H t
pLH
― 0.15 0.5
Propagation
delay time
H→L t
pHL
― 0.15 0.5
Output rise time t
r
― ― ―
Output fall time t
f
5
I
F
= 8mA
V
CC1
= +15V, V
EE1
= −15V
R
L
= 200Ω
― ― ―
μs
Common mode transient
immunity at high level
output
C
MH
V
CM
= 600V, I
F
= 8mA
V
CC
= 30V, Ta = 25°C
−5000 ― ― V / μs
Common mode transient
immunity at low level
output
C
ML
6
V
CM
= 600V, I
F
= 0mA
V
CC
= 30V, Ta = 25°C
5000 ― ― V / μs
All typical values are at Ta = 25°C
Test Circuit 1 : I
OPH
Test Circuit 2 : I
OPL
Test Circuit 3 : V
OH
Test Circuit 4 : V
OL
8
1
4
V
CC1
0.1μF
V
OL
V
F
R
L
V
EE1
V
8
1
4
V
CC
0.1μF
I
OPL
A
V
6-5
8
1
4
V
CC1
0.1μF
V
OH
V
I
F
R
L
V
EE1
8
1
4
V
CC
0.1μF
I
OPH
V
8-6
I
F
A