Datasheet
TLP127
2007-10-01
4
Switching Characteristics
(Ta = 25°C)
Characteristic Symbol Test Condition Min. Typ. Max. Unit
Rise time t
r
― 40 ―
Fall time t
f
― 15 ―
Turn−on time t
on
― 50 ―
Turn−off time t
off
V
CC
= 10 V, I
C
= 10 mA
R
L
= 100 Ω
― 15 ―
μs
Turn−on time t
ON
― 5 ―
Storage time t
s
― 40 ―
Turn−off time t
OFF
R
L
= 180 Ω (Fig.1)
V
CC
= 10 V, I
F
= 16 mA
― 80 ―
μs
Recommended Operating Conditions
Characteristic Symbol Min. Typ. Max. Unit
Supply voltage V
CC
― ― 200 V
Forward current I
F
― 16 25 mA
Collector current IC ― ― 120 mA
Operating temperature T
opr
−25
― 85 °C
Note: Recommended operating conditions are given as a design guideline to obtain expected performance of the
device. Additionally, each item is an independent guideline respectively. In developing designs using this
product, please confirm specified characteristics shown in this document.
Fig. 1 Switching time test circuit
I
F
V
CC
V
CE
R
L
V
CC
V
CE
I
F
t
ON
t
OFF
t
s
9V
1V